Dissertation > Excellent graduate degree dissertation topics show

1000MW Unit Induced Draft Fan Configur Ation Scheme Reform Research and Simulation

Author: LiuLin
Tutor: DiYongJie
School: North China Electric Power University
Course: Pattern Recognition and Intelligent Systems
Keywords: 1000MW induced draft fan simulation modeling control scheme testscheme
CLC: TK223.26
Type: Master's thesis
Year: 2012
Downloads: 63
Quote: 0
Read: Download Dissertation

Abstract


As one of largest energy dissipation equipment, energy saving potential of power fan is very large. In response to the policy of the country’s energy consumption and pollution reduction, for1000MW unit desulfurization renovation project, after introducing the technology of together the boosting fan and induced draft fan as a organic whole, jiangsu province power design institute put forward a new kind of induced draft fan configuration, based on the traditional two sets of induced draft fan, increase a induced draft fan, namely three machines run in parallel with induced draft fan. Three sets of induced draft fan configuration, can not only at different load operate different number of fan, flexible change fan operation quantity, improving the boiler efficiency, and not need to change the original6KV electric wiring way into the10KV, saving the project investment.But, three sets of induced draft fan configuration is whether feasible, reliable and safe, and how to design the related control system, and this is the study of this paper. On the basis of jiangsu province electrical design institute provided the specific equipment of1000MW unit (boiler, turbine, electric and all auxiliary systems), and for the three sets of induced draft fan configuration, in simulation platform established on the corresponding mathematical model, through the dynamic characteristic test verified the accuracy of model, then design the fuel, air supply, wind and hearth negative pressure and a complete set of control system, through a series of fixed value disturbance and RB (RunBack, fast load rejection) test under different unit load, verified the correctness of control logic, so as to prove the feasibility of and safety of the three sets of induced draft fan scheme, finally from the three aspects of adaptability, economy, and the safe reliability to compare three sets configuration and two sets of induced draft scheme, and the results show that the three set induced draft fan scheme in the three aspects are superior. The significance of this paper is to provide theory basis and technical support for the realization of the three set induced draft fan scheme, and the control scheme designed in this paper provide technical guidance for its realization.

Related Dissertations

  1. Research on the Laws of Nitrogen and Phosphorus Loss and Control Scheme in Eryuan Rural,X712
  2. High-speed interconnect signal integrity studies,TN41
  3. Digital Electro-hydraulic Control System and Its Research in 1000MW Unit,TM621.6
  4. 1000MW steam turbine control and protection system analysis and design,TM621
  5. Simulation System Modeling and Analysis for Technical Operation of Railway Marshalling Station,U292.16
  6. Application and Research of Frequency Control Technique on Induced Draft Fan Renovation,TM621.7
  7. Series hybrid electric vehicle performance analysis software system design and research,U469.7
  8. Modeling and Simulation for Operation System of Railway Container Freight Station,U294.3
  9. Cold stretch rolling equipment control system,TP273
  10. The Research on Operational Risk Control of Internet Banking in China,F832.2
  11. Study on Compressive Deformation Behavior of Pure Mo Powder Sintered,TF124.5
  12. Research on the Construction Design of Project Long-Jian-Long 500KV Transmission Line,TM75
  13. Control Scheme for Inhibiting Inverter Harmonic Current in Five-Phase Induction Motor,TM346
  14. Performance Numerical Analysis on a Static Blade Adjustable Axial Flow Induced Draft Fan in 600MW Power Unit,TM621.7
  15. The Design and Implementation of Circuit Breaker’s Operating Mechanism,TM561
  16. Servo presses 80t overall design and simulation analysis,TG305
  17. Control Schemes for LCL-VSR under Unbalanced Supply Voltage Conditions,TM461
  18. User-oriented Frontal Crash Safety Analysis for Medium-sized Bus in a Small Batch,U467.14
  19. Development and Application of Control Program of the Opposed Multi-burner Coal Water Slurry Gasification Technology,TQ546
  20. Modeling of Non-point Source Pollution in Wetland Systems-A Case Study in the HuoLin River Watershed,X52
  21. Operation Control and Analysis of Microgrid Based on the Microturbine Generation System,TM76

CLC: > Industrial Technology > Energy and Power Engineering > Steam Power Engineering > Steam boiler > Boiler constructed > Combustion devices > Ventilation cited wind equipment
© 2012 www.DissertationTopic.Net  Mobile