Effect of different oxidation time on the structure properties of microarc oxide film on the surface of pure titanium

Author: SunYuanYuan
Tutor: ZhaoBaoDong
School: Qingdao University
Course: Clinical Stomatology
Keywords: Pure titanium Micro-arc oxidation Oxidation time Surfacemorphology
CLC: R783
Type: Master's thesis
Year: 2012
Downloads: 78
Quote: 0
Read: Download Dissertation

Abstract


Objective:Comparing the influence of different oxidation time on the structural properties of the titanium surface to explore the feasibility and superiority of the micro-arc oxidation (MAO) applied to the implant surface treatment.Methods:50 TA2 titanium plates with specification of 24mm×1.0mm were chosen and numbered randomly.40 were randomly chosen as experimental group, which were given micro-arc oxidation treatment. They were divided into four groups, namely, MAO-5、MAO-10、MAO-20 and MAO-30, according to different oxidation time(5minutes, 10minutes,20minutes and 30minutes). Ten titanium plates left were control group without micro-arc oxidation treatment. Sample surface morphology observation, roughness detection, composition and structure analysis were done by using scanning electron microscope (SEM), surface roughness tester, X-ray diffraction (XRD)and energy dispersive X-ray spectrometer (EDX). The data were statistically analyzed.Results:(1) Surface film of titanium plates in the experimental group presented gray-white and gritty appearance, with no metallic luster. While titanium plates in the control group showed bright and smooth surface, with silver metallic luster.(2) Surface views of titanium films in the experimental group under SEM were porous and honeycomb, with a three-layered section:the skin layer was loose while the inner layer was dense. Pores on the film were small and evenly distributed in MAO-5 group, while pores were bigger with uneven distribution in MAO-10 group; pores in MAO-20 group were very different in sizes, with ridgy rim like craters; pores in MAO-30 group were much bigger and overlapping, with uneven distribution, and sintering particles and liquation could be observed on the surface film. Surface of titanium plates in the control group appeared roughly parallel grooves under SEM.(3) Surface roughness measurements of titanium plates in the experimental group were (0.70±0.51)μm, (1.21±0.57)μm, (1.42±0.55)μm and (1.60±0.81)μm for the corresponding MAO-5. MAO-10, MAO-20 and MAO-30 group, while that in the control group was (0.32±0.33)μm. Surface roughness measurements were significantly different among the four MAO groups as well as between the experimental and control groups.(4) Titanium, oxygen, calcium and phosphorus elements were detected in the surface film of titanium plates in the experimental group, while no calcium and phosphorus elements in the control group. The ratios of atoms of calcium to phosphorus were 0.95,1.47,1.63 and 1.96 for group MAO-5, MAO-10, MAO-20 and MAO-30 respectively.(5) With the oxidation time extended, the diffraction peaks of rutile and anatase titanium dioxide in the micro-arc oxidation film were weakened, while the diffraction peak of crystal hydroxyapatite was enhanced. No diffraction peak of crystal hydroxyapatite was observed in the control group.Conclusions:(1) Micro-arc oxidation (MAO) films can form after different treated time (10min to 30min) at a voltage of 450 V in the electrolyte contained calcium acetate and sodium dihydrogen phosphate.(2) Different oxidation time has significant influence on pore size, morphology and thickness of the titanium film.(3) Surface roughness of the titanium plates is increased after micro-arc oxidation treatment, and will increase with the oxidation time prolonged.(4) The ratios of atoms of calcium to phosphorus is 1.63 in the micro-arc oxidation film, which is similar to that of hydroxyapatite in human body.(5) Surface film after micro-arc oxidation treatment contains rutile and anatase titanium dioxide as well as crystal hydroxyapatite.(6) The micro-arc oxidation (MAO) technology has certain advantages and feasibility in improving the surface properties of titanium implant.

Related Dissertations

  1. Preparation of Micro-Arc Oxidation Ceramic Coating on Mg Alloy and the Research of Galvanic Corrosion,TG174.453
  2. Preparation, Characterization and Performance of the Bio-coatings on the Surface of Pure Titanium Based on Micro Arc Oxidation,R318.08
  3. AZ91D magnesium alloy micro-arc oxidation Jin Duicheng bone cell adhesion , proliferation and ALP activity,R318.08
  4. Studies on HA Coating Treated by Microarc Oxidation on Porous Implants of a New β Titanium Alloy,R687.4
  5. The Study of Hydroxyapatite Coatings and Hydroxyapatite Powder,R318.08
  6. Preparation and Property of Bioactive Antibiotic Ceramic Coatings on Titanium,R318.08
  7. Effects of Surface Modification on Biocompatibility of Magnesium Alloy AZ811,R318.08
  8. Microstructure and Bioloigical /Mechanical Properties of Microarcal Ti6AL4V Alloy Coated by Microarc Oxidation,R318.08
  9. Study on Surface Modification of AZ81 Magnesium Alloy by Micro-arc Oxidation and Coating’s Drug Release,R318.08
  10. Strontium hydroxyapatite on osteoblast biological behavior,R318.08
  11. The Influence of Different Treatment for Pure Titanium Surface on the Mineralization of Marrow Mesenchyma Stem Cell,R783.1
  12. Study on Preparation and Property of V2O5 /TiO2 Composite Film Via Microarc Oxidation,TB43
  13. Research on Preparation of High Purity Titanium by Molten Salt Electrolytic Refining Process,TG146.23
  14. Study on the Preparation of Micro-Arc Oxidation Coating on Aluminum LC4 and Its Characteristic,TG174.453
  15. Preparation and Corrosion Resistance of Bio-Ceramic Coating by Micro-Arc Oxidation on Magnesium Alloy,TG174.453
  16. Formation Mechanism and Tribological Properties of Micro-arc Oxidated Coating on Aluminium,TG174.453
  17. Study on Application of TA2 Industrial Pure Titanium on Seawater Piping System,TG146.23
  18. Finite Element Simulation and Experiment of Cold Forming Processing for Ti-based Composite Pipe Fittings,TG306
  19. Study on Processing and Surface Properties of Double Glow Plasma Niobizing and Oxygenizing on Medical Titanium,TG174.445
  20. Research on Electrochemical Micromachining of Pure Titanium,TG662
  21. Investigation on Process, Microstructure and Performances of Microarc Oxidation Coating on ZK60 Magnesium Alloy,TG174.453

CLC: > Medicine, health > Oral Sciences > Oral orthotics
© 2012 www.DissertationTopic.Net  Mobile