Dissertation > Excellent graduate degree dissertation topics show
Magnetorheological technology fuze postponed release insurance institutions
Author: WangWeiQing
Tutor: WangZuo
School: Nanjing University of Technology and Engineering
Course: Weapons systems and the use of engineering
Keywords: Fuse Magnetorheological fluid Delay Arming Delay Arming time Flow field analysis
CLC: TH112
Type: Master's thesis
Year: 2011
Downloads: 16
Quote: 0
Read: Download Dissertation
Abstract
|
The magnetorheological fluid extension Arming magnetorheological fluid is applied to the fuze delay arming with high safety, high Arming reliability Delay Arming time adjustable simple structure, etc.. Delay arming of the fuze magnetorheological fluid is still in the theoretical stage of exploration, and there is the problem of imperfect design theory, magneto-rheological fluid materials prone to precipitation phenomena. Using theoretical analysis, numerical simulation and experimental validation of the method of combining insurance magnetorheological fluid fuze extension lift the study of the following aspects: 1. Theoretical analysis and calculation, design on the basis of previous studies, and processing the fuze magnetorheological fluid Delay Arming prototype. The magnetorheological fluid hydrodynamic theory fuze magnetorheological fluid Delayed Relief insurance institutions Delay Arming asked mathematical model to arrive at the institutions Delay Arming time formula. At the same time the use of the Ansys software simulation analysis of the correctness of the extension Arming time formula. The simulation results show that: the formula can be used as a reference mechanism design formula. Magnetorheological fluid precipitated combined fuze use of environmental requirements as well as the characteristics of magnetorheological fluid proposed several measures to improve the stability of magnetorheological fluid precipitation and commercial magnetorheological fluid improved preparation of a new magnetorheological fluid test results show that the prepared magnetorheological fluid to solve the the sedimentation stability problems, magnetorheological fluid applied to the fuze delay arming. 4 design and completion of static tests and dynamic tests of the bodies prototype. The safety performance of the static test research institutions and arming reliability. Pilot test system using homemade projectile speed, discharge aperture, magnetorheological fluid parameters, the influence of temperature on the institutions Delay Arming time, test results showed that the impact of the law with the theory and simulation results is consistent. Dynamic test program, designed in accordance with the Langley method to complete the institutional dynamic test. The test results show that: in the the 1959 howitzer 130 mm Cannon environment, the extension of the agency arming distance greater than 100m institutional security, reliability, delayed arming distance meet the design requirements. Finally, the work of this study are summarized in the thesis completed work and innovation, and the prospect of future research work.
|
Related Dissertations
- Mine Risk Information Integration and Intelligent Early Warning,X936
- Sort learning loss function studies,TP181
- New tamping unit design and characteristics of electro-hydraulic shaker,U216.6
- Sculpture in the Landscape of Modern Urban Studies,J313.2
- The Physiological Adaptation of Mitochondrial Fusion and Fission to Aging and Endurance Training in Rat Muscle,G808.1
- Research on the Mr Damper Control System and Experiment of Shear-type Mr Damper,TB535.1
- The Research for the Reduction Degree and Imaging Studies and Clinical Effect of Mild Spondylolytic Spondylolisthesis,R687.3
- On Integration of the Continent CBA League Matches and Taiwanese SBL League Matches,G841
- Simulation of Flow Field in Adapter between Twin-Screw Extruder and the Die,TQ320.5
- Micro and small explosive train design,TJ430
- Hyperspectral Anomaly Target Detection,TP391.41
- Analysis and Design of Magnetorheological Fluid Brake,TB381
- Fuze Ball Rotor small caliber dual safety system design,TJ430
- Development Analysis of China Buddha Sculpture,B948
- Control System Designing and Comprehensive Performance Experiment Analysis on the Interventional Micro-robot,TP242.2
- The Confliction and Combination of the Civil Custom of Xinjiang Minitory and the Civil Law,D923
- The Research Integration with Ideological and Political Work of Private Enterprise and Corporation Culture,F270
- The Analysis of Flow Field of Automotive Power Steering Gear and the Optimized Designation for Pumping Oil Machine,U467
- Integration and participation: Intellectuals and the New Rural Construction,D422.6
- On Popular Singing Method’s Relationship with the Traditional Learning Blending and Innovation,J616
CLC: > Industrial Technology > Machinery and Instrument Industry > Mechanics (mechanical design of the basic theory ) > Of mechanism
© 2012 www.DissertationTopic.Net Mobile
|