Dissertation > Excellent graduate degree dissertation topics show

Development of CT’s High Voltage Generator Filament Driving Power Supply

Author: ZengHaiQing
Tutor: ZouHao
School: Northeastern University
Course: Biomedical Engineering
Keywords: resonance PWM soft-switch closed-loop control error amplifier
CLC: TM46
Type: Master's thesis
Year: 2009
Downloads: 48
Quote: 0
Read: Download Dissertation

Abstract


Generator is an essential part of the CT. Its performance impacts the image of CT directly. This paper is based on High Voltage Generator, focuses on the filament driving power supply. This research is carried out to meet the requirements of diverse detection methods of CT. It is funded by National Digital Medical Imaging Equipment and Engineer Technology Research Center, and design a real-time and self-adjusting filament driving power supply.Taking PWM as the base method, this thesis constructs a filament driving power supply which can adjust filament’s current. Firstly, based on the requirements of function, Safety rules and EMC, adopt the direct current formed by rectifying 380VAC, the same method to the main inverter. Secondly, analyse the structure resonance and PWM, adopt PWM as the method and design half bridge single-phase buff soft-switch circuit, simulate its the course,and it can reduce the power loss.Fanally,design a close loop control circuit,adding PI adjuster and error compensator, adjust filament feedback current according to the set current.Taking UC3525 as the main adjuster, a hign performance power supply which contains a variety of modules is designed. The frequency of switch is setted to 40KHz. Design a filament current setting circuit including two choices, It can meet the requirements of the High Generator when it’s exposed or unexposed. Design a magnetically coupled circuit to drive power mosfet, which can work efficiently when the frequency is not too high, and reduce the complexity, guarantee the value of mA when exposing, compare the set current with the feedback current detected by current transformer, the error is adjusted and sent to the inner comparator of UC3525 to control pulse width and make the filament current stay steady state. Beside these, considering the power supply protection, adopt transient voltage suppressor, surge suppressor and fuse to protect the circuit, and the feedback current is sent to the main control system to deal through interface. It’s measured that the greatest error of the filament current is 3.2%, the least reaches 0.2%, the feedback current is compatible with the set current, which satisfies the requirement.

Related Dissertations

  1. Model of Cylinder Controlled by On-Off Valve and System of PWM Control,TH138
  2. Study on the Control System for Automatic Aiming of HWIL Pitching Mechanism,TJ303
  3. Study on LC Resonance Charge and POS Based Pulsed Power Supply,TN782
  4. Study on the Fluorescence Analysis of Penicillins Antibiotics,R155.5
  5. MRI Guoded Experimental Cryoablation of Rabbit’s Sciatic Nerve for MRI and Pathology Contrast Study,R445.2
  6. The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
  7. Diffusion Tensor Imaging Study of Idiopathic Epilepsy at 3.0T High Field Magnetic Resonance Scaner,R445.2
  8. Studies on the Interaction between Biomolecules by Surface Plasmon Resonance Technology and Fluorescence Spectrometry,Q503
  9. The Application Value of Magnetic Resonance Diffusion Tensor Imaging in Skeletal Muscle Tumor,R445.2
  10. A Study of Wallerian Degeneration in Cortico Spinal Tract after Cerebral Infarction by fMRI,R445.2
  11. A Volumetric Study of External Capsule, Extreme Capsule and Inferior Frontal Gyrus White Matter in First-Episode Paranoid Schizophrenia,R749.3
  12. Healthy Chinese central olfactory structures related to MRI volume and olfactory function with age correlation,R445.2
  13. Multislice CT and MRI angiography in the diagnosis of Takayasu arteritis,R445.2
  14. 3.0T BOLD MR techniques on acute unilateral ureteral obstruction of renal damage,R693.2
  15. Progressive supranuclear palsy clinical and magnetic resonance imaging characteristics of,R741
  16. 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
  17. MR diffusion weighted imaging in Application Value of osteonecrosis,R681.8
  18. Fractional Differential resonance boundary value problems,O175.8
  19. Categories of Second Order Ordinary Differential Equations Existence,O175.8
  20. Magnetic field spin chain entanglement dynamics of particles in both,O413.1
  21. Imprinted Polymer Preparation and application of solid-phase extraction,O631.3

CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > Converter
© 2012 www.DissertationTopic.Net  Mobile