Dissertation > Excellent graduate degree dissertation topics show
Development of High-Precision Continuous Scanning Inductance Transducer
Author: GaoLingYan
Tutor: WangLei
School: Harbin Institute of Technology
Course: Instrument Science and Technology
Keywords: Precision measurement Roundness instrument Inductive sensors Sensitivity Nonlinear correction
CLC: TP212
Type: Master's thesis
Year: 2011
Downloads: 24
Quote: 0
Read: Download Dissertation
Abstract
|
Micro-displacement measuring device compared to the capacitive sensor grating sensors, inductive sensors with high sensitivity, good reproducibility, and relatively stable performance advantages, there is a wide range of applications in the the roundness instrument system for ultra-precision machining and measurement occasions . Recent years, in cylindrical and roundness measurements, inductance measurement accuracy of the sensor with the increasingly high demand for the measurement accuracy of the rotary parts more and more people's attention, and its development has become a roundness instrument The major limiting factor of the measuring instruments. The sum of the mechanical structure of the sensor head in order to further improve the accuracy of the measurement of the inductance of the sensor system, it is necessary to adopt two measuring circuit performance improvement at the same time. This this subject in The Institute has developed a sensor system based on its low sensitivity, nonlinear serious problem, and make improvements design and the comparative experimental verification. Of this work: First, starting from the solenoid type coil structure model, based on the principle of Bi Aosafaer electromagnetic field analysis of the sensitivity of the magnetic field characteristics of the coil structure; and from the angle of the magnetic measurements of the electrical conversion circuit to improve the sensitivity studied and analyzed. Effective measures proposed for the improvement of the system sensitivity, the coil structure itself and the specific improvements of the measurement circuit design, such as a coil and the core, material selection, dimensions parameter optimization, the choice of voltage and frequency of the excitation signal source, the range switching modules of the application and so on. Second, by the large number of experiments carried out on the original system, the discovery and analysis of nonlinear problems. Analysis of its influencing factors both from the mechanical structure and the measurement circuit, nonlinear correction method introduced a the nonlinear compensation package for the system, and program for system software program to achieve the system of non-linear correction. Again, for the the positioning problems encountered in the roundness measurement, especially in the measurement system designed sampling trigger control module, time sampling data control, ensure repeatability roundness data acquisition, more reliable evaluation of roundness . Inductive sensor system of comparative experiments, to verify the validity of the improvements made this topic its performance. The experimental results show that the sensitivity of the system to improve more than doubled, the nonlinearity error from 3.4% to 0.41%, also improved system stability and repeatability.
|
Related Dissertations
- The Effect of Composite Additive on the SNCR,X701
- Infrared Imaging Target Simulation Resistance Array Control System Development,TJ765.4
- Study on a Pneumatic Manipulator Clamping Force Control System Based on H ∞ Control Theory,TP241
- Preparation and Properties of Chitosan-based Thermosensitive Composite Hydrogel,R943
- Isolation and Identification of Avian Pathogenic Escherichia Coli from Chicken and Characterizations of Its Virulence-Associated Genes,S852.61
- Luoyang Land the Use and Ecoloqical Environment Construction Coordination Study,X171
- Cloning and Characterization of Photoperiod Sensitive Gene ZmELF4 in Maize,S513
- Change and Value of Serum Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 in Acute Coronary Syndrome,R541.4
- Effects of Telmisartan on hs-CRP and HMW-adiponectinin Patients with Essential Hypertension,R544.1
- Study on Clinical Value of High-sensitivity Cardiac Troponin T Assay in Myocardial Infarction,R542.22
- Correlation Analysis between Coronary Lesion Severity and Peripheral Blood Cell CD34~+ Ratio in the Coronary Heart Disease Patients Complicating Diabetes Mellitus,R541.4
- The Study on Clinical Using of FISH and Cytology in Diagnosis and Surveillance of Recurrence in UC,R737.1
- Application and Significance of CISS Classification and TOAST Subtype on Ischemic Stroke (Attach 210 Cases Analysis),R743.3
- Ankle-brachial index combined ultra- sensitivity C-reactive protein determination of the value of coronary artery disease,R541.4
- Ischemic stroke and carotid atherosclerosis and related biochemical hs-CRP and LDL-C changes,R743.3
- Aloe anthraquinones enhanced UV radiation on plant protection,X173
- Automatic Calibration System Voltage Monitor,TM933.2
- Research on NO-reference Image Quality Assessment Based on HVS,TP391.41
- Study of Static and Dynamic Collaborative Optimization on Container Ship Structure,U674.131
- A Study of Some Analysis Properties for Fractal Interpolation Functions,O174.42
- Reliability-based Sensitivity Research on Multi-span Rotor System,TH113
CLC: > Industrial Technology > Automation technology,computer technology > Automation technology and equipment > Automation components,parts > Transmitter ( converter),the sensor
© 2012 www.DissertationTopic.Net Mobile
|