Dissertation > Excellent graduate degree dissertation topics show

Impedance Automatic Testing and Analyzing System for the Multichannel Flexible Thin-Film Microelectrode Array

Author: XiaNianSheng
Tutor: ChaiXinYu;SuiXiaoHong
School: Shanghai Jiaotong University
Course: Biomedical Engineering
Keywords: visual prosthesis flexible thin-film microelectrode array electrochemical impedance automatic testing and analyzing system electrode evaluation
CLC: R318.0
Type: Master's thesis
Year: 2012
Downloads: 31
Quote: 1
Read: Download Dissertation

Abstract


Vision is the main source for the human to get information from the outside world, and blindness affects the quality of our life not only physically but also mentally. Nowadays, visual prosthesis is one of the focuses of visual function restoration research. This artificial device gathers and encodes outside image information, and then applies the electrical signals to microelectrode array to induce phosphenes in visual cortex. As the key component of visual prosthesis interacting with visual nerve tissue, the electrochemical impedance is an important evaluation parameter of the microelectrode. So, it is crucial to evaluate the electrochemical performance of the microelectrode array in vitro. With the development of MEMS (Micro-Electro-Mechanical System) techniques and performance requirements of electrode, multichannel flexible thin-film microelectrode array (MEA) has become the important component of retinal prosthesis. The traditional technique for testing multichannel flexible thin-film MEA may cause damage to the electrode. Meanwhile, mass and complex manual operation owing to high-number electrodes would cause measurement errors with low efficiency. Apparently, this traditional testing method can not meet our demands yet.Therefore, a set of impedance automatic testing and analyzing system used three-electrode testing equipment is developed by analyzing the electrochemical theory at the electrode-electrolyte interface, and used to test and analyze the electrochemical impedance of retinal microelectrode array in this thesis. The system can automatically test the impedance by the virtual instrument control of testing instruments and multichannel switches, automatically draw the impedance and phase spectrum chart for each channel, and then calculate the mean and variance values of the whole electrodes impedance and phase, Besides, all the data can be saved as an Excel file. A simple, efficient, high-precision approach to impedance automatic testing, data automatic analysis and processing, and filing of the system provide an effective evaluation method for the MEA impedance.

Related Dissertations

  1. Electrochemical Studies on Interaction between ApoCopC、BSA and Cu(Ⅱ)、Cu(Ⅰ)、Cd(Ⅱ)、Ag(Ⅰ),O646
  2. Detection Technology of MicroRNA-21 for Non-small Cell Lung Cancer,R734.2
  3. Study of Microbial Corrosion in Central Air-conditioning Cooling Water System,TU831.4
  4. Electronic devices ITO film electrode of copper and Corrosion Behavior of,O484
  5. Research of Power and Data Wireless Transmission System for Visual Prosthesis,R318.1
  6. Sc-containing high strength Al-Zn-Mg-Cu-Zr alloys and corrosion behavior of homogenization,TG146.21
  7. Electrodeposition of Fe-ni Alloy Foil,TQ153.2
  8. Study on the Degradation of Organic Coatings and Substrate Metal Corrosion by Combined WEB and EIS Techniques,P734
  9. Synthesis and Inhibition Performance of Novel Dissymmetric Bisquaternary Ammonium Salt,TG174.42
  10. Formation and Electrochemical Real-time In-situ Characterization of Self-assembled Monolayers of Mercaptan on Gold Electrodes in Nonaqueous Solution,O622.7
  11. The Semiconductor and Electrochemistry Study of Zinc Injection Technique Inhibition Metal Corrosion in Primary Water of Pressurized Water Reactor,TL375.6
  12. Phase Plane Analysis of FCM Model and Its Response to Electrical Stimulation,R774
  13. Fabrication and Application of Electrochemical/Biological Sensors Based on Chemically Modified Electrode,TP212.3
  14. Electrochemical Corrosion Characteristic of Direct Current Pulsed Plasma Sourse Nion AISI 304 Stainless Steel,TG156.82
  15. The Research on Preparation and Properties of Thermal Barrier Coatings on Carbon Steel,TG174
  16. Research on Measurement Methods of Electrochemical Impedance Spectroscopy of Lithium-Ion Battery,TM912
  17. The Study of Label-Free Impedimetric Immunosensor for AFB1,TP212
  18. Research on Measurement Method of Mocrobiologically Influenced Corrosion in Cooling Water,TG172.7
  19. Research of Solvent-Free and Flame Retardant and Anti-Corrosive Epoxy Coatings,TQ630.7
  20. Attachment and Application and Electrocatalytic Behavior of Catalase Biosensor and Electrochemical Investigation of Coordination between Eu3+ and Centrin,Q504
  21. A Study on Evaluation Techniques of Servicing Anti-corrosive Coatings Properties for Oil Tanks,TG174.4

CLC: > Medicine, health > Basic Medical > Medical science in general > Biomedical Engineering > General issues
© 2012 www.DissertationTopic.Net  Mobile