Dissertation > Excellent graduate degree dissertation topics show
Static Security Analysis of Enterprise Network
Author: LiuXin
Tutor: ZhouXueSong
School: Tianjin University of Technology
Course: Proceedings of the
Keywords: Petrochemical grid static security N-1 criterion PSASP probability risk analysis
CLC: TM711
Type: Master's thesis
Year: 2011
Downloads: 74
Quote: 0
Read: Download Dissertation
Abstract
|
With the rapid development of China’s national economy, more and more electricity is needed and the requirement of the power quality also will be getting higher and higher. Once the system is turned into failure, it may soon spread to the whole system and cause system crashes which leads to large-scale power outages if we do not handled properly, which will cause serious consequences and even lead to huge economic and social losses. Tianjin Petrochemical grid, as the enterprise grid, also has this problem. At the same time, it also has some of their own problems: its load is the primary and secondary industrial load and should be ensured the continuity and quality of its power supply; in the phaseⅢproject, the increased large ethylene and oil refining load make the grid load capacity and installed capacity increased a lot and the network structure of the system will be changed more complex. So the probability of failure also increases. As a result, it will become the central issue of the petrochemical project to verify system security and ensure its safe and stable operation.Firstly, the paper introduces recent main methods and basic analysis principle of network security assessment. Moreover, the methods above are applied to the petrochemical grid network combining with corresponding calculation modules in PSASP respectively, and they are: uncertainty evaluation methods, probabilistic evaluation method and the risk assessment method. Considering the several methods have different analyzing emphasis and different interested grid vulnerable points, so different conclusions will be got. However, this is the exact complementary perfectly incarnates security dynamic condition of the entire SINOPEC grid, assissing relevant personnel to find out the troubles hidden in grid and put forward corresponding suggestions and countermeasures.Specifically, These factors that whether the integrated power grid can meet the load rate in a variety of operating modes and the requirements of N-1 rule in security criteria or achieve certain reliability rate can be used to inspect the power grid.There are also other aspects that we used,such as determine better connection mode and operation mode of the sinopec power system using fault tree analysis and whether risk indicators of power grid can be running at the state which is low enough and so on.Finally, the conclusion that Tianjin SINOPEC has high security level and reliability has been confirmed. What’s more, the analysis thinking can be applied to other power grid or system on the basis of successful research in SINOPEC power system so as to draw another some meaningful conclusions which is useful for operating personnel.
|
Related Dissertations
- Research on Effectiveness Evaluation Methods of Weapon Systems,TJ06
- Research on Dam-Break Probability Analysis Method for Dangerous Reservoir,TV697
- Key Technologies of Dam-break Life Loss Risk Assessment Research,TV122.4
- The Analysis and Technique Research on Innovative Questions for High School Entrance Examination,G633.6
- Stochastic Optimal Dispatch of Power System Considering Uncertain Line Failures under Extreme Weather Disaster,TM73
- Research on Peer-to-Peer Traffic Identification Algorithm Based on Cluster Analysis,TP393.02
- Exact Observability of Stochastic Time-Varing Systems and Weak Stability of Discrere-Time Stochastic Time-Invariant Systems,O231
- The Study on Choice of Policy Tools of China,D630
- Application of Risk Analysis Technique by Combination of Qualitative and Quantitative Methodology in LNG Terminal Projects,F426.22
- Risk-based radar software system testing Strategy,TP311.53
- Some losses renewal equation equivalent conditions for asymptotic,O211.67
- Any area on the uniform design and construct,TQ460.1
- Research on Projects Management Model of Non-operating Government-invested Projects,F284
- Study on UAV Borne Dual Combination of Wide Angle Digital Camera Image Data Processing Methods,P231
- The Risk Analysis and Precaution in the Application of Efficient Soft Foundation Treatment Equipment,TU71
- Standards of corporate opportunity,D922.291.91
- A Feasibility Study of the United Heavy Industry Company Moving Loans under the Out of City into Park Policy,F832.4
- Research on the Reform of the Criterion of Offense by Amount,D924.13
- Model Selection for Longitudinal Data Based on the Quadratic Inference Function under a Simple Order Restriction,O212.1
- Network Groups Study under Momern Network Technology,N02
- PID Controller Design of Linear Systems with Time Delay Based on Parametric Space and GUI Simulation,TP273
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Theory and Analysis > Network analysis,power system analysis
© 2012 www.DissertationTopic.Net Mobile
|