Dissertation > Excellent graduate degree dissertation topics show
The Suppression for DC Bias on Transformer Neutral Point
Author: LiuZongWei
Tutor: BaiBaoDong
School: Shenyang University of Technology
Course: Motor and electrical
Keywords: Transformer DC magnetic bias DC potential compensation Compensate for power
CLC: TM406
Type: Master's thesis
Year: 2010
Downloads: 203
Quote: 1
Read: Download Dissertation
Abstract
|
With the development of electric power of China 's \transmission equipment produce certain adverse effects, such as transformer neutral point of the DC magnetic bias phenomenon . This phenomenon adversely affect the performance of the rms value of the excitation current , the higher harmonic components , and the corresponding increase in loss , a core height of saturation will cause the increase in the leakage flux , and consequent local overheating , insulation aging problem. This research mainly inhibition caused by the earth DC current DC magnetic bias arising from the earth DC current , there are two ways , one is the earth magnetic storm caused power grid in the low-frequency circulation ( relative to the 50Hz frequency current than equivalent DC ) , the main east-west grid . Second is the monopole operation , the DC transmission to earth as a running loop . The suppression method corresponds to the earth caused by the DC current DC biasing three kinds : neutral point of series resistance , the neutral point DUBLE DC bit Compensation Act . Three methods have their own advantages and disadvantages , the first two methods to consider itself safe operation of the factors and substation relay protection parameters such as pressure, temperature of the resistance and capacitance factors , these two methods is suitable for small - and medium - capacity transformer . DC bit Compensation Act do not need to consider other factors , can be directly attached to , but need to consume a lot of power , suitable for the larger capacity transformer . Demand should a substation , according to the mechanism of DC magnetic bias , as well as a - DC compensation suppression method , design and production of a DC offset power to suppress the neutral point of the transformer DC magnetic bias the compensation power can be maintained at the DC current of the neutral wire within the range allowed by a transformer , while the power supply control system can detect and display the size of the current neutral line of the DC current .
|
Related Dissertations
- The Equivalent Circuit Model of Radial Vibration Mode Piezoelectric Transformer and Its Application,TM406
- Study on the Mechanism of Partial Discharge Emitting Ultrasonic Wave and Propagation Property Within Power Transformers,TM855
- Substation Integrated Early Warning System and Application,TM76
- Design and Implementation of petrochemical enterprises substation operation system,TP311.52
- Dynamic Voltage Restorer Based on Super-capacitor,TM761.1
- Fuzzy Control System Design of Transformer Cooler,TP273.4
- Research on Signal Processing Unit of Optical Voltage Transformer,TM451.6
- Research of Embedded Merging Unit Based on IEC61850,TM45
- Research on Electronic Voltage Transformer Based on Capacitive Voltage Divider,TM451
- The Research of Electronic Current Transformer and Its Communication Interface,TM452
- Calibration and Online Monitoring System for Electronic Transformer Based on IEC61850-9,TM45
- Research on Series Resonant High Voltage Capacitor Charging Power Supply,TM53
- The Study on the Method of Structural Dynamic Modeling and Analysis of Wind Power Transformers,TM41
- The Simulation Renserch of New Series Hybrid Active Power Filter and Some Related Problems Analysis,TN713.8
- Conventional Substation Analysis and Design of Renovation Project of Integrated Automation,TM63
- Research on Installation and Testing Technique on 500kV Three Phases Compact Transformer,TM407
- Research on Trigger System of Surface-breakdown High-voltage Switch,TM564
- Electronic Voltage Transformers and the Harmonic Voltage Measurements,TM451
- Research on Dynamic Voltage Restorer Based on Three Single-phase H Bridge,TM464
- Optimal Power Flow Control Based on Electronic Power Transformer,TM76
- Design of Merging Unit Based on Embedded FPGA,TM45
CLC: > Industrial Technology > Electrotechnical > Transformers, converters and reactors > General issues > Testing,operation