Dissertation > Excellent graduate degree dissertation topics show
Ventilation Optimization in Nuclear Power Plant Turbine Room
Author: FengZhen
Tutor: LiuGang
School: Donghua University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Turbine Housing Airflow Numerical Simulation Building structure Inducing fan Similar model test Neutral surface
CLC: TU834
Type: Master's thesis
Year: 2010
Downloads: 75
Quote: 1
Read: Download Dissertation
Abstract
|
In the case of the world's growing energy shortages, China's energy situation is not optimistic, building energy efficiency to ease the energy shortage in China is of great significance. Nuclear power plant steam turbine room ventilation by mechanical air intake, the mechanical exhaust the program, making the investment costs and energy consumption greatly increased, so the guarantee process case, reasonable introduction of natural wind, natural ventilation mechanical exhaust ventilation combined with great significance. Arranged in the form of the nuclear power plant steam room there is a big difference and heat and thermal power stations, heat pipes and ancillary systems are many and complex, but the surface temperature is low. In this regard has not been associated design procedures, the design work produced confusion. Fuqing nuclear power plant steam room ventilation program and its various influencing factors to the present and future of such design projects to evidence-based commissioning party's request, the numerical simulation and optimization, and in accordance with the principle of similarity than to establish the kind of 1/20 model test station. Firstly, using CFD technology to simulate the original condition (natural ventilation, mechanical ventilation scheme) of the Fuqing nuclear power plant steam turbine room. Realizable k-ε turbulence model and DO radiation model numerical calculation on the flow and temperature fields of the turbine room, good agreement of the results obtained with the Qinshan Phase II Turbine Housing measured temperature, thereby verifying the numerical simulation is reliable 's. And on this basis can be distributed on the plant within the layers of air volume, Face average temperature, speed, and surface \layers of windows position, size; trench width; inducing fan settings and Selection) optimization direction. Simulation results show that: when the nuclear power plant steam turbine room with natural ventilation, mechanical exhaust ventilation program: roof fan pressure head 60Pa, from top to bottom layers into the windscreens than when 1:1.2:5.4:3.2 most economical and reasonable , and at this time should be to minimize 0m Layer C side window position and to increase the area of ??the side windows; trench width of 3m, the most economical and rational plant ventilation; inducing fan flow 860M to 3 / h, and is provided in the grid have heat The most obvious effect of the gate (or hanging objects hole) below 3.5m at. This result will not only be able to be directly used for the construction of a specific project, an important reference value for similar power stations and similar buildings ventilation programs, as well as the formulation of the structural parameters.
|
Related Dissertations
- The Setting Bases of Working Pressure in LNG Systems and Orthogonal Experiment Design of Heat Exchangers,TQ051.5
- Study on Springback of High-Strength Steel Stamping,TG386
- Numerical Simulation and Experiment on Hydroforming of Cups with Controllable Radial Pressure,TG386
- Research on Technology and Mechanism of Joining Cemented Carbide to Carbon Steel,TG454
- Numerical Simulation of Film Cooling in Turbine Cascade with Non-Axisymmetric Endwall Method,V231.3
- High Speed Aerodynamic Convection and Coupled Heat Transfer of Complicated Bodies,V215.4
- The Analysis on Characteris of Vibration Source about Vertical Vibration of Surrounding Environment Induced by Rail Transit,U211.3
- Study on the Heat Transfer Characteristics of Particle Cluster in Circulating Fluidized Bed,TK124
- Numerical Simulation of SNCR Process of a 600MW Utility Boiler,TK222
- Numerical Simulation of Biomass Direct Reburning,TK16
- Numerical Simulation on Pulverized Coal Combustion Process in a 670T/H Tangential Firing Furnace,TK224.11
- Numerical Simulation on the Combustion Process in the Furnace of a 1000MW Lignite-Fired USC Boiler,TK224.11
- Study on Gas-Solid Two-Phase Flow in Spouted Beds,TK173
- Experimental Study and Numerical Simulation on Aerodynamic Field of Tangential Bias Swirl Burner,TK223.23
- Characteristic Study of Combustion in Central Reverse Flame Chamber,TK223.21
- Numerical Simulation and Contrastive Analysis of Labyrinth Seals and Leaf Seals,TK263.2
- Numerical Study on Phosphorus Distribution in Water Environment of the Three Gorges Reservoir,X832
- The Design and Performance Simulation of External Valve Small Displacement Pump,TE933.3
- Analysis of the Impact of Tailings Dam Stability under Seepage Role,TV649
- Study on Hydraulic Fracturing of Low Permeability Reservoir,P618.13
- Numerical Simulation and Experimental Study of Air-Assisted Sprayer of Orchard,S491
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Ventilation, dust,air purification,dehumidification
© 2012 www.DissertationTopic.Net Mobile
|