Abstract


ObjectiveTo evaluate the reliability and accuracy of spectrophotometer and the effectiveness of gingival in visual shade-match in vitro model.MethodsThe spectrophotometer was used to measure the color parameters (CIE1976 L*a*b*) of incisal, body, cervical area of two shade guides(VITA 3D-Master, Shofu Vintage NCC) repeatedly for the reliability assessment and the accuracy assessment, and also the color parameters (CIE1976 L*a*b*) of incisal, body, cervical area of 42 tabs of Shofu Vintage NCC shade guide fixed in 4 kinds of gingival-indicator for the gingival shade guide effectiveness assessment inside a black box.ResultsReliability of spectrophotometer was as follows:VITA 3D-Master: incisal(96.9%±1.8%), body(89.2±3.4%), cervical(89.2%±3.2%); Shofu Vintage NCC: incisal(75.2%±3.0%), body(82.9%±2.9%), cervical (83.3%±3.0%).There was no significant difference among three areas(p>0.05). The concordance rate of VITA 3D-Master was higher compared to Shofu Vintage NCC(p<0.05).Accuracy of spectrophotometer was as follows:VITA 3D-Master:incisal (76.2%±7.2%), body (86.9%±4.7%), cervical (74.6%±6.8%); Shofu Vintage NCC: incisal(48.1%±5.2%), body(74.3%±4.8%), cervical(57.6%±5.9%). The concordance rate of body area was higher compared to other areas(p<0.05). The concordance rate of VITA 3D-Master was higher compared to Shofu Vintage NCC(p<0.05).△E value of VITA 3D-Master:incisal (1.88±0.09) NBS, body (1.12±0.10) NBS, cervical (1.48±0.10) NBS;△E value of Shofu Vintage NCC:incisal (1.83±0.14) NBS, body (1.16±0.07) NBS, cervical (1.67±0.08) NBS. The△E of body area was lower compared to other areas(p<0.05). There was no significant difference between two kinds of Shade guide (p>0.05).The effectiveness of gingival shade guide (△E value) was as follows:incisal (0.61±0.29) NBS, body (0.51±0.27) NBS, cervical (2.93±0.79) NBS. The△E of cervical area was higher compared to other areas(p<0.05). There was no significant difference among Gumy、2、3、4 groups (p>0.05).ConclusionsThis in vitro study showed a varying degree of reliability and accuracy for Spectrophotometer depending on the type of shade guide system used and the region of shade, Spectrophotometer showed good repeatability and accuracy, could be used in clinic; The gingival color has an effect on the cervical of tabs, while has little effect on the incisal and body, and there are no significant differences statistically in comparison among different color; Suggest using one color gingival shade when taking visual shade match.

Related Dissertations

  1. A Study of Three Types of Metal Ceramic Restoration on the Color Difference,R783.1
  2. The Chrome Study of Chinese Teeth in Vivo and Shade Guide in Sichuan,R783.3
  3. The Chroma Study of Chinese Maxillofacial Derma in Sichuan,R783.3
  4. Study of Computer Color Matching of Maxillofacial Prosthesis,R782.2
  5. Study on the Color and Aging Properties of Dental Y-TZP Ceramics,R783.1
  6. Application on Colorimetry of Rubies’ Color Assessment,P619.281
  7. Research and Realization of Remote Digital Proof,TS805
  8. A Study of the Relationship between Ultrasound Images of Masicatory Muscle and Caraniofical Morphlogy of Young Males with Nomal Occlusion,R783.5
  9. Experiments Study of BIO-OSS on PRP Composite Repairing Bone Defect around Metal Nail of Pure Titanium,R783.6
  10. Root Resorption of Upper Centre Incisor with Compensation in Skeletal Class Ⅱ and Ⅲ Malocclusions,R783.5
  11. Several Low Flat Mandibular Alveolar Ridge to Improve Denture Retention Methods of Clinical Experience,R783.6
  12. The Dual-phase Treatment of Skeletal Class Ⅲ Malocclusion.,R783.5
  13. The Combined Treatment of Complex Adult Angleclass Ⅱ Division 1,R783.5
  14. To Observe the Effect of Different Dental Filling Technologies on the Microleakage under Confocal Laser Scanning Microscope,R783
  15. The Clinical Evaluation on Gingival Aesthetics of Immediate Implant and Immediate Prosthesis of Maxillary Anterior.,R783.6
  16. Comparison of Differences on Osseointegration among Immediate Implant, Delayed Implant after Bone Graft and Delayed Implant at Different Time,R783.6
  17. Evaluation of between the Occlusal Force and the Tissues Health Surrounding Implant of ITI Implants with Zirconia All-ceramic Crown,R783
  18. The Experimental Study on Effect of Different Low-power Laser Irradiation on Osseointegration of Dental Implants,R783.6
  19. The Influence on the Dimensional Stability and Elastic Deformation Caused by Two Types of Disinfectant Solution to Different Impression Material,R783
  20. Expression of BMP-1 in Periodontal Tissues during Orthodontic Tooth Movement in an Animal Experimental Study,R783.5
  21. Micro-implant Anchorage in Adults with Type of Open Bite Treatment,R783.5

CLC: > Medicine, health > Oral Sciences > Oral orthotics > Dental Materials Science
© 2012 www.DissertationTopic.Net  Mobile