Clinical Study of IOL Master for Measurements of Axial Length and Corneal Curvature before and after Removal of Silicone Oil

Author: XiaoJing
Tutor: MaXiang
School: Dalian Medical University
Course: Ophthalmology
Keywords: IOL Master Axial Curvature of the cornea Silicone oil
CLC: R779.6
Type: Master's thesis
Year: 2010
Downloads: 76
Quote: 0
Read: Download Dissertation

Abstract


Objective: To compare silicone oil removal before and after surgery IOL Master and other commonly used clinical instrument accuracy of axial length and corneal curvature measurement , to investigate its clinical characteristics . Methods : analysis of 34 cases cataract extraction plus vitrectomy combined with silicone oil tamponade in patients with axial length measurements using the IOL Master and A , respectively, before and after silicone oil removal , the IOL Master corneal curvature measuring the curvature of the cornea . Results : 1.IOL Master measurement silicone oil removal preoperative axial length was 24.18 ± 2.11 mm and postoperative axial length was 24.12 ± 1.98mm , A ultra measurement silicone oil remove preoperative axial length was 32.77 ± 3.41 mm axial growth after 24.33 ± 2.03mm. The measuring results of the IOL Master axial length before and after surgery the difference was not statistically significant ( P = 0.369 ) A super- axial length measurements before and after surgery , a significant difference ( P lt; 0.01 ) ; preoperative two instruments the measurement results are significant differences (P lt; 0.01), and the measurement results of the two instruments after the difference was not statistically significant ( P = 0.062) . 2.IOLMaster measurement silicone oil removal preoperative corneal curvature of 42.81 ± 2.41 D, corneal curvature to 42.89 ± 2.32D ; keratometer measured pre-operative corneal curvature was 42.46 ± 2.13D , corneal curvature was 42.55 ± 2.12D . The IOL Master keratometer There was no statistically significant difference in corneal curvature measurements before and after silicone oil removal . Silicone oil removal preoperative the IOL Master keratometer measurements mean difference -0.35D ( keratometer -IOL Mastr ) , the 95 % limits of agreement for -2.49 to 1.79D ; poor results after silicone oil removal both measurement the value of the mean -0.34D ( keratometer -IOL Mastr ) , the 95 % limits of agreement for -2.37 to 1.69D . Conclusion : For silicone oil removal before and after the axial length measurement the IOL Master 's accuracy is higher than supine contact A ??super : For the measurement of the curvature of the cornea , IOL Master more accurate than keratometer .

Related Dissertations

  1. Development of the Platform for Compressor Optimization Design and Aerodynamic Optimization Design in the Transonic Compressor,TH45
  2. Development of the On-Line Electronic Gauge for Crackshaft’s Axial Length Parameters,TH822
  3. Risk Factors for the Development of Transient Hypotony after Sinlicone Oil Removal in Aphakia Eyes,R779.6
  4. Correlation of Branch Retinal Vein Occlusion and Ocular Axial Length、 Anterior Chamber Depth,R774.1
  5. The Analysis of the Growth Factor Related with the Secondary Glaucoma in the Anterior Champer of Silicone Oil-filled Eyes,R779.6
  6. The Clinical Evaluation of Measuring the Horizontal Sulcus to Sulcus Distance by Ultrasound Biomicroscopy,R770.4
  7. Mechanical Property Analysis on Concrete Short Columns with Strengthened Style Hoop,TU375.1
  8. The Preparation of Modified Siloxane Surfactant and Its Application in Emulsifying Silicone Oil,TQ423
  9. Study on Yield Mechanism of Reinforced Concrete Frame Structure’s Strong Column-Weak Beam under Rare Earthquake Action,TU275
  10. No leakage electric pump Loss Analysis and axial force balance new method for research,TH38
  11. Field Test Research on the Vertical Load-bearing Characteristics of Bridge Pile Foundation in Steep-slope Area of Qinba Mountain Region,U443.15
  12. Clinical Application of IOL Master in Patients before and after Laser-assisted in Situ Keratomileusis,R779.63
  13. Design and Synthesis Axially Chiral Phosphiamines Ligand by Using a Stereocontrol System,TQ203.2
  14. The Experimental Investigation and Nonlinear Finite Element Analysis of Z-Shaped Column’s Shearing Performance Subjected to Low-Cyclic Horizongtal Load,TU375.3
  15. Influence of Column Axial Force to Weld Internal Force at Beam-to-column Joint in All-welded Steel Frame,TU391
  16. In Vitro Study on the Effects of Different Medicine to Silicone Oil Emulsification,R779.6
  17. Study on Dynamic Modeling and Boundary Identification of Axial Compression Column Under Different Pressures,TU311.3
  18. IOL Master biometry and IOL power calculation clinical observation,R318.1
  19. Numerical Simulations of Solute Taylor Dispersion in Capillary,TQ021.1
  20. CFST stub columns of Carrying Capacity,TU398.9
  21. GFRP reinforcement poles Experimental study of axial compression,TU366.2

CLC: > Medicine, health > Ophthalmology > Eye surgery and surgery
© 2012 www.DissertationTopic.Net  Mobile