Dissertation > Excellent graduate degree dissertation topics show
Study on Three-Phrase Multiloop Power Comprehensive Monitoring System Based on ATT7022B
Author: HuChangLun
Tutor: GongMaoFa
School: Shandong University of Science and Technology
Course: Power Electronics and Power Drives
Keywords: multi-loop ATT7022B power monitor three-phrase and three-wire system time-sharing multiplexing theory
CLC: TM76
Type: Master's thesis
Year: 2011
Downloads: 109
Quote: 0
Read: Download Dissertation
Abstract
|
With the rapid development of our economy, loading power increases rapidly.The demand for power become larger and larger, meanwhile, the customers make higher request to the quality of electricity. With the power electronics and other nonlinear equipments widely applied in power system, harmonic that can lead to the quality of power become worse and worse and sometimes even threat the safety of power and damage to electrical equipments has increasingly generated. The electricity monitoring instrument can record the abnormal parameters of supplying power, which can provide timely and reliable evidences for settling the problems.In the thesis, power monitoring device of three-phase multi-loop adopted the advanced electric power measurement technology, can measure the real-time power parameters, such as voltage, current, power etc. It contains many functions which not only can set the power measurement standards according to peak, flat, valley time of power but also transmit the recorded data to the host computer through RS485 and Ethernet, realizing centralized monitor to the high-voltage customers as many as 20.Both medium voltage grid and special mine grid adopt the operation mode of neutral line indirectly grounded. In the thesis, I also monitor and take note of electrical parameters in the three-phase and three-wire operation mode system. Combined with the hardware implementation, I put forward some theories about energy measurement in such an operation mode.The paper take the "Host CPU+slave measuring chip" method, the former manage the energy measurement chips ATT7022B while the latter record six or seven loop circuits of electrical signal. Application has proved that the study has many unique characteristics, on the one hand it can ensures the real-time and measurement precision in the comprehensive monitoring device, on the other hand, it also save the hardware resources as far as possible. Time-sharing multiplexing technology has been used in the software. In order to reducing the error, a particular algorithm applies to amend power value which is inaccurate during the sampling process by using the time-sharing multiplexing technology. In the final, I analyses the influences that all kinds of error affect on the measurement precision and then put forward an error compensation algorithm.I designed the three-phase multi-loop power comprehensive monitoring device based on the theoretical analysis. At the end, I correct the device precision by using Henan STAR calibration instrument. After operating for a period of time, the experimental results prove that three-phase multi-loop monitoring instrument has a high precision, good reliability, well stability in practical operation.
|
Related Dissertations
- Optimization Research on Parts of Thermal Process Control System in Anshan Iron and Steel Group Corporation’s Second Power Plant,TM621.6
- Control Technology for Square-wave Voltage Driven Multi-phase Induction Motors,TM343
- Design on Malfunction Detect System for Low-Voltage Distribution Networks Based on GSM/GPRS,TN929.5
- Research on Power Monitor System for Multi-node Seafloor Observatory Network,TM76
- Generator stator winding single-phase ground fault of digital simulation and traveling wave positioning,TM303.3
- Recognition Study of Turbo-generator Rotor Winding Inter-turn Short Circuit Fault Based on Multi-loop Theory,TM311
- Design of Distribution Transformer Monitoring Terminal (TTU) Based on ARM,TM764
- Research on Internal Electrical Faults of Synchronous Generator,TM307.1
- Power and Environmental Monitoring System CSC, LSC Program to Explore and Achieve,TP277
- Research of Digital Control and Main Circuit of High Power Inverter,TM464
- Research on the Digital Control System for 400Hz Inverter Based on Repetitive Control,TM464
- Cable Automatic Monitoring System Design and Test,TN929.11
- Study on Stator Ground Fault Simulation and Monitoring Online for Generators,TM862
- Research and development of a new type of optical channel power monitor,TN929.11
- Recogntion Study of Turbo-generator Rotor Winding Inter-turn Short Circuit Fault Based on Multi-loop Theory,TM31
- Multi -level DC converter technology of Buck,TM46
- Clinical Effects on Anterior Open Bite in Adults: A Comparison between Microscrew Anchorage and Multiloop Edgewise Archwire,R783.5
- Design and Research of Integrated Electric Power Monitoring Device on Power Network,TM76
- Research on Intelligent Electric Power Monitor,TM76
- Research on Control Strategy of Grid-side Converter for Wind Power Generation,TM614
- Three-phase squirrel cage induction motor rotor fault intelligent diagnosis method,TM343
CLC: > Industrial Technology > Electrotechnical > Transmission and distribution engineering, power network and power system > Power system automation
© 2012 www.DissertationTopic.Net Mobile
|