Dissertation > Excellent graduate degree dissertation topics show

Postoperative Transcutaneous Blood-oxygen Saturation Assay for the Continuously Monitoring of Vascular Crisis of the Free Flap

Author: HanDong
Tutor: ChenChuanJun;LiZhiLai;ZhangZhiHong
School: Anhui Medical University,
Course: Clinical Stomatology
Keywords: Free flap Vascular crisis Oxygen saturation Dynamic Monitoring
CLC: R622
Type: Master's thesis
Year: 2008
Downloads: 55
Quote: 0
Read: Download Dissertation

Abstract


Purpose of rabbits in the lower abdomen superficial epigastric artery flap model to simulate free flap various types of vascular crisis , evaluate percutaneous oxygen saturation (SP02) monitoring method in the dynamic monitoring of free flap vascular crisis after the application value. Methods 30 rabbits disinfection, skin preparation, making bilateral lower abdominal superficial epigastric artery flap were randomly divided into three groups : group blocked artery , vein occlusion group , arteriovenous blocked group . Using microsurgical vascular clamp block and vascular recanalization with reflective pulse oximetry monitor flap SP02 percutaneous dynamic measurement of changes, and with the flap color, temperature change time for comparison. Results 106 ± 37s after arterial occlusion flap minimize percutaneous SP02 threshold recanalization after 178 ± 17s rebounded to normal levels . Vein occlusion , the flap SP02 begins as a disorder and volatility , 198 ± 26s SP02 after reaching the minimum threshold of 635 ± 37s after recanalization gentle rise to normal levels. Vein occlusion decline and recovery group was significantly longer than the time difference artery occlusion group (P lt; 0.001). Whole blood after blocking SP02 fall time and time and arterial occlusion recanalization were similar . Flap temperature, color changes significantly longer than flap SP02 change time . Conclusion Percutaneous SP02 noninvasive and simple measurement method can be sensitive , objective, continuous , quantitative reflection of flap perfusion , which is earlier than temperature changes , such as changes in color performance . Pulse oximetry monitors inexpensive, simple, reliable, easy to operate, repeatability , etc., is an objective condition monitoring flap blood supply of the best instrument to use with compatible clinical observation . And be able to take advantage of wireless electronic engineering technology , continuous , real-time , non-invasive dynamic monitoring , early detection of vessel thrombosis and embolism flap type and automatic alarm notification medical staff , for the rescue flap save time.

Related Dissertations

  1. GIS and GPS- based Land Resources dynamic inspection system design and implementation,P208;P228.4
  2. MSP430-based human signal detection and alarm system,TN911.23
  3. Study on Formation Mechanism and Optimization of Comprehensive Treating about Large Thick Loess Landslide,P642.22
  4. The Research on Land-cover Remote Sensing Dynamic Change in Zhuzhou City,S159.2
  5. Research on Supporting Technology of SAGD Intermittent Steam Injection,TE345
  6. Dynamical Monitor and Analysis of Suspended Sediment Concentration by Remote Sensing in Caofeidian Offshore Areas,P714.1
  7. The Study of Immunological Function of Obstructive Sleep Apnea Hypopnen Syndrome,R766
  8. The Land Use/cover Dynamic Monitoring Ecological Environment and Driving Forces of Meishan City, Sichuan Province,P237
  9. Study on Dynamic Monitoring Technology of Forest Resource,S757
  10. Studies on Non-invasive and Wireless Monitoring System of Oxygen Saturation of Blood,TH772
  11. Design and Study on the Dynamic Monitoring Information System of Urban Land Price,F293.2
  12. Study on Dynamic Monitoring and Temporal-Spatial Distribution of Land Value in Rizhao City,F301.2
  13. Based on multi-feature classification comparison Urban Remote Sensing Dynamic Monitoring,TP873
  14. Monitoring of New Construction Land Using High Resolution SPOT5 Imagery,P237
  15. Forearm Free Flap Reconstruction of Oral and Maxillofacial Soft Tissue Defection,R782.2
  16. Application of Photoacoustic Microscopy in Cerebral Hypoperfusion Model of Rats,R743.3
  17. Screening and Analysis of Coagulation Factor Ⅷ Inhibitor and Development Related Factors in Hemophilia a Patients,R554.1
  18. Key Valve Operation Dynamicmonitoring and Real-Time Reporting System,TP274.4
  19. Soldier system life parameters detection technology,E916
  20. The Research on Establishenment of Dynamic Monitoring System for Drynaria Roosii Nakaike Resource Survey,S567.9
  21. The Design of High Rock Slope,TU45

CLC: > Medicine, health > Surgery > Plastic Surgery (repair surgery ) > Plastic surgery school
© 2012 www.DissertationTopic.Net  Mobile