Dissertation > Excellent graduate degree dissertation topics show
Stochastic Heat Transfer Analysis on Buried Pipe of Ground Source Heat Pump with Monte-Carlo Method
Author: ChenDeChao
Tutor: ChenZhiHua
School: Wuhan University of Technology
Course: Structural Engineering
Keywords: buried pipe Monte-Carlo method stochastic finite element sensitivity
CLC: TU831
Type: Master's thesis
Year: 2010
Downloads: 38
Quote: 0
Read: Download Dissertation
Abstract
|
With the development of society and gradually forward of the urbanization process, there is more and more building energy consumption. However, due to the energy shortage, energy conservation and emission reduction in buildings has become the focus of attention. Because of the energy conservation and environmental protection, the technology of ground source heat pump(GSHP) has been rapidly applicated and promote in building.In this paper, after reading a large number of the papers about ground source heat pump, many random factors has been found in heat transfer process of ground source heat pump. In order to reflect the randomicity of these parameters and research the heat transfer characteristics of buried pipe more accurately, a stochastic model was applied for heat transfer of buried pipe, some stochastic parameters (such as inlet temperature, soil temperature, soil density, etc) were chosen and assumed that its satisfy uniform distributions. The outlet temperature, the quantity of heat exchange and theirs sensitivity with these parameters were analyzed with Monte-Carlo stochastic finite element method. The main work are as follows:Established the mathematical model of buried pipe. The model was divided into two parts. One part was fluid flowing model in U-tube, the other was the soil heat transfer model of pipe radius around the temperature distribution;Analyzed the statistical characteristic of random factors in the heat transfer process of ground source heat pump, such as thermal properties of soil, soil temperature, inlet temperature, velocity of fluid, depth and effective radius of U-tube, et al;Simulated the operating conditions of buried pipe of ground source heat pump in summer, established the fluid—solid coupling model by FLOTRAN CFD and obtained the distribution of temperature field. Then, It was established the stochastic model by Latin Hypercube Sampling method, used probability method to analysis the outlet temperature and quantity of heat exchange which reflect characteristics of heat transfer, and analyzed the sensitivity of their with the each random parameters;Analyzed the change rule of outlet temperature and quantity of heat exchange with inlet temperature, soil temperature, internal velocity, thermal properties of soil, depth and effective radius of U-tube and the other parameters which influence the performance of heat exchanger. Analyzed the reasons for the change rule, consider both the outlet temperature and quantity of heat exchange, were given the parameters of the optimal design advice.
|
Related Dissertations
- The Effect of Composite Additive on the SNCR,X701
- Transient Thermal Analysis of Multi-Body System with Complicated Boundary Conditions,TK124
- Study on a Pneumatic Manipulator Clamping Force Control System Based on H ∞ Control Theory,TP241
- Preparation and Properties of Chitosan-based Thermosensitive Composite Hydrogel,R943
- American Option Pricing under Stochastic Market Option Model Based on Dividend and Treatment Fees,O211.6
- Isolation and Identification of Avian Pathogenic Escherichia Coli from Chicken and Characterizations of Its Virulence-Associated Genes,S852.61
- Luoyang Land the Use and Ecoloqical Environment Construction Coordination Study,X171
- Cloning and Characterization of Photoperiod Sensitive Gene ZmELF4 in Maize,S513
- Change and Value of Serum Soluble Lectin-Like Oxidized Low-Density Lipoprotein Receptor-1 in Acute Coronary Syndrome,R541.4
- Effects of Telmisartan on hs-CRP and HMW-adiponectinin Patients with Essential Hypertension,R544.1
- Study on Clinical Value of High-sensitivity Cardiac Troponin T Assay in Myocardial Infarction,R542.22
- Correlation Analysis between Coronary Lesion Severity and Peripheral Blood Cell CD34~+ Ratio in the Coronary Heart Disease Patients Complicating Diabetes Mellitus,R541.4
- The Study on Clinical Using of FISH and Cytology in Diagnosis and Surveillance of Recurrence in UC,R737.1
- Application and Significance of CISS Classification and TOAST Subtype on Ischemic Stroke (Attach 210 Cases Analysis),R743.3
- Ankle-brachial index combined ultra- sensitivity C-reactive protein determination of the value of coronary artery disease,R541.4
- Ischemic stroke and carotid atherosclerosis and related biochemical hs-CRP and LDL-C changes,R743.3
- Individuals with type 2 diabetes, serum complement factor H, hs-CRP levels and insulin resistance study,R587.1
- Aloe anthraquinones enhanced UV radiation on plant protection,X173
- To Explore the Value of Plasma NT-proBNP and Hypersensitive C-reactive Protein in Evaluating the Prognosis of the Patients with Acute Coronary Syndrome,R541.4
- Automatic Calibration System Voltage Monitor,TM933.2
- Research on NO-reference Image Quality Assessment Based on HVS,TP391.41
CLC: > Industrial Technology > Building Science > Housing construction equipment > Air-conditioning, heating, ventilation,and its equipment > Air-conditioning
© 2012 www.DissertationTopic.Net Mobile
|