Dissertation > Excellent graduate degree dissertation topics show
A commercial building air conditioning energy simulation and testing research
Author: WangShuaiBin
Tutor: LiuGuoDan
School: Qingdao Technological University
Course: Heating,Gas Supply, Ventilation and Air Conditioning Engineering
Keywords: Commercial buildings Building energy Energy simulation Field Test
CLC: TU201.5
Type: Master's thesis
Year: 2010
Downloads: 126
Quote: 0
Read: Download Dissertation
Abstract
|
As China's energy-saving work, the large public building energy efficiency has attracted much attention. In this paper, Tsinghua University Building Energy Center developed a large public building energy sub-metering real-time monitoring and analysis system as the basis for the conduct of a commercial building energy simulation and experimental study , the test data processing and analysis , evaluation mall energy use , on this basis , gives the corresponding energy-saving recommended . Firstly, the use of air-conditioned buildings BIN method to calculate energy consumption , according to the mall distribution system diagram and field research results to develop energy testing program , and the air conditioning energy consumption on-site testing , calibration BIN method is used to simplify the calculation of the energy project feasible. The principle of using statistics to evaluate the level of building energy consumption , compared with non-air- conditioning season, seasonal differences in monthly total power consumption , power consumption per unit area of air conditioning season is 37.63 ~ 49.13 kWh / m , rather than air-conditioning power consumption per unit area of the season for the 28.59 ~ 31.13 kWh / square meters , the annual total power consumption per unit area of 411.9 kWh / m ; using least squares method to obtain monthly total average monthly electricity consumption and the outdoor dry bulb temperature regression coefficient , and the mall building energy saving status evaluation . The experimental test data analysis showed that the annual energy consumption of air conditioning systems account for the largest proportion was 42% ; followed by a light socket , the ratio was 33.5%. Chiller COP is low, only 4.0 , the system supply and return water temperature is about 3 ℃ , the system is in big flow, small temperature operation. The same time through the indoor illumination and temperature and humidity test analysis showed that the indoor temperature and humidity according too large and there is a serious uneven . To solve the above problems , this paper uses a combination of theoretical analysis and experimental methods, refrigeration units, water systems , cooling towers, air conditioning end run to analyze the situation , and the corresponding energy-saving measures . Through the utilization of the energy consumption of the mall , you can basically Qingdao area energy use in commercial buildings have some understanding of the situation , to summarize existing building energy use of such problems , the future of China's large public buildings energy use quota management, building energy transformation to provide basic data and reference on the work of building energy efficiency in-depth research and extension has a certain significance .
|
Related Dissertations
- Trial Research on the Small Straw Burying and Mud-liquid Mixing Equipment for the Machine of Straw Back into Field Using in Paddy Field,S224.29
- Development of Light-duty Paddy Planter,S223
- A New Rail Crack Remote Monitoring System,U213.4
- The Study of Complex Monitoring for Energy Transfer Based on Temperature Field Reconstruction,TU111
- Buildings Energy Efficiency Analysis System Based on Thermal Parameters Measurement and On-line Reconstruction,TU111.195
- Performance Test and Evaluation of Smart Antenna in TD-SCDMA Outfield,TN821.91
- Research and Application of OTTV in the Cold Winter and Hot Summer Region,TU831
- Rock dug large cutter suction dredger cutter cutting force calculation and analysis,U674.31
- Shanghai typical office building energy consumption and its influencing factors in the application of LEED standards,TU111.195
- Public building energy monitoring and energy efficiency assessment study,TU85
- Campus energy -saving monitoring platform key technology development and building energy performance evaluation,TU111.195
- Permanent magnetic coupling design and key technology research,TN622
- Application of heat pipe heat loss compensation heavy wellbore Research,TE358
- A regional cooling and heating energy consumption Simulation Methods,TU831.2
- Passive heating and building thermal performance analysis methods,TU832
- Field Test Research on the Vertical Load-bearing Characteristics of Bridge Pile Foundation in Steep-slope Area of Qinba Mountain Region,U443.15
- Study on Trajectory and Velocity Measurement Method of Particle Field by Digital Holography,O438.1
- Research and Application on Thixotropic Cement Slurry,TE256
- Research on Energy Storage and Economic Analysis of Green Residential Building in North China,TU201.5
- Panzhihua Iron and Steel Xichang vanadium and titanium steel base back to fill in the pile negative friction resistance research,TU473.1
- Research on the Evaluation of Building Energy-saving Based on the Improved Value Engineering Method,F206;F224
CLC: > Industrial Technology > Building Science > Architectural design > General issues > Design principles, the principles and management > Building energy efficiency design
© 2012 www.DissertationTopic.Net Mobile
|