Dissertation > Excellent graduate degree dissertation topics show

Establishment and Rudimentary Application of the Method of Recording Electrically Evoked Auditory Brainstem Responses

Author: ChengJingNing
Tutor: ZhangQiuHang;CaoKeLi
School: Peking Union Medical College , China
Course: Otorhinolaryngology
Keywords: EABR Cochlear Implant Auditory Neuropathy/dys-synchrony Inner Ear Malformation Ossified Cochlea Leukodystrophy
CLC: R764
Type: Master's thesis
Year: 2008
Downloads: 42
Quote: 0
Read: Download Dissertation

Abstract


[Objective]To establish the method of recording electrically auditory brainstem responses (EABR) in cochlear implantation .[Methods]37 patients due to different causes (including auditory neuropathy, ossified cochlea, Inner Ear Malformation, abnormal white matter, having a history of meningitis, etc.) and of different ages were tested with EABR during cochlear implantation. They were divided into two groups. The first group (20 cases) received a bipolar electrical stimulation from electrodes of cochlear implants after implantation surgery. EABR waveforms were recorded by GSI Audera evoked potential instrument. Based on the data of the first group, the second group (17 cases) was mono-polar electrically stimulated with a balanced two-phase pulse current before implantation, using modified cochlear implant connected to an in vitro speech processor as the stimulation device, and with self-made spherical iridium-platinum alloy electrode as positive stimulation electrode placed in round window niche. EABR was recorded by Bio-logic Navigator Pro evoked potential instrument. It has been preliminarily used in some special cases.[Results]Clear EABR waveforms were recorded in all 37 cases. In the first group, EABRⅡ~Ⅴwaveforms were recorded in all 20 patients, and some also have I waveform recorded. The average latencies of waveformⅢandⅤwere 2.04±0.20ms and 3.96±0.41ms respectively, with average response threshold at 148.46±11.63CL(current level). In the second group, EABR waveformsⅡ~Ⅴwere recorded in all 17 cases. The average latencies of waveformⅢandⅤwere 2.12±0.18ms and 4.18±0.19ms respectively, with average response threshold at 220.0±16.04CL. This group includes two cases of auditory neuropathy, seven cases of inner ear malformation, one case of cochlear ossification, two cases of abnormal white matter, and one case of having a history of meningitis. Well-differentiated waveform were recorded in all of them.[Conclusion]EABR is an objective nerve electrophysiological testing method that accurately reflects functional completeness of auditory pathway. It has an great value in making the judgement whether patients can acquire auditory response after cochlear implantation, especially for the patients without any residual hearing and with suspicious auditory neuropathy . This method is safe, gives high emission of auditory response and therefore is worthy of spreading to application.

Related Dissertations

  1. Speech Processing Algorithm Base on Auditive Perception for Cochlear Implant,TN912.3
  2. A Contrastive Study of English and Chinese Academic Book Review from the Perspective of APPRAISAL Theory,H319
  3. Study on Inner Ear Malformation for Its Classification and Relationship with SLC26A4 and GJB2 in Patient with Sensorineural Hearing Loss,R764.43
  4. Electrically evoked auditory brainstem response in cochlear implant research and clinical application,R764
  5. Hearing Loss Induced by Electrode Insertion Trauma: Mechanisms and the Effect of Retinoic Acid in Inner Ear,R764.83
  6. HRCT Analysis of Inner Ear Malformation and Deafness Gene Mutations in Chinese Pedigrees with SNHL,R816.96;R450
  7. REZ - type 1 adult language deaf artificial cochlear implant after the clinical application and related basic research,R764
  8. Children's speech audiometry design vocabulary and cochlear implantation in prelingual deaf children 's speech recognition,R764
  9. Design and Experiment on Implanted Receiver-stimulator and Electrode Array of Cochlear Implant,R764
  10. The Design of Cochlear Implant’s Speech Processing Circuit and Its Experimental Test,R318.6
  11. Study of Laboratory Cochlear Implant,R764
  12. Fitting in Children Cochlear Implantees Using Neural Response Imaging and Evoked Stapedius Reflex,R764
  13. Studies on Correlation between Electrical Auditory Properties and Speech Perception of the Post-lingual Deafened Cochlear Implant Users,R764
  14. The Analysis of Phonetic Features in Prelingual Deafness Children with Cochlear Implant and the Research about It with Genetic Correlation,R764
  15. Preattentive Processing of Chinese Tones in Cochlear Implant Recipients and Electric Stimulation on Cochlea Related to Cochlear Implantation,R764
  16. A Study on Acoustic Signal’s Pickup by an Experimental Minisize Piezoelectric Ceramic Sensor,R318.18
  17. Study of Speech Enhancement in Cochlear Implant Based on Characteristics of Hearing,TN912.3
  18. Study on Aural Rehabilitation with Cochlear Implant and Standardization of Mandarin Sentence Lists for Children Speech Perception Assessment,R764.43
  19. The Analysis of Speech Recognition Abilities of Deafness Children Treated with Cochlear Implants or Hearing Aids under Different Noisy Condition,R764
  20. Research of Auditory and Speech Therapy for Deaf Children with Cochlear Implant,G762;H08

CLC: > Medicine, health > Otorhinolaryngology > Otology,ear disease