Dissertation > Excellent graduate degree dissertation topics show

The Preliminary Observation of CD34 Antibody Coated Stents to Prevent In-stent Stenosis of Artery Injured by Balloon

Author: CaoHuaMing
Tutor: SuHai;WangXiaoHua
School: Jiangxi Medical College
Course: Internal Medicine
Keywords: CD34 antibody Stand Narrow Endothelial precursor cells
CLC: R541.4
Type: Master's thesis
Year: 2005
Downloads: 74
Quote: 2
Read: Download Dissertation

Abstract


Objective: observed in rabbits CD34 antibody coated stent ability to reduce and prevent the the balloon injury stent stenosis . Method : 1. Bracket Development : Comparative gelatin and low molecular weight dextran two stents package substrate , identified by gelatin as a package substrate stent coated , and then package the CD34 antibody . 2 animal model : the left and right femoral artery of New Zealand white rabbits using balloon injury , immediately after injury to the common stent implantation on the right , the left implant antibody bracket ; 14 days sampling a 45 days sampling 3 . OUTCOME MEASURES : ① angiography : stent narrow Percentage : narrow lumen in% = (stent diameter - the diameter of the narrowest point ) / stent diameter × 100 % . The ② pathological examination of the stented segment artery neointimal : OUTCOME MEASURES stent neointimal hyperplasia percentage . Calculate the the bracket enclosed area ( EEM ) , the arterial lumen area that endothelial cells surrounding area ( Lumen ) , neointimal area ( N ) = EEM - Lumen . Cross section artery percentage of N = ( the EEM - lumen ) / the EEL x 100 % ; the ③ bracket at both ends of the arterial wall. : To observe the indicators for both ends of neointimal hyperplasia . (4) data processing and statistics : All data are mean ± standard deviation , using a paired t-test . Results: 1.14 days , the antibody stent segment artery neointimal hyperplasia was significantly lower than the ordinary bracket side . 2.45 days, compared with the ordinary bracket , antibody-coated stent stenosis percentage was significantly down on the ordinary side of the bracket ( 16.13 ± 3.93 VS 47.03 ± 11.89 , P lt ; 0.05 ) ; 3 . The stent segments artery neointimal : antibody package artery stent segment neointimal percentage than ordinary stent segment arteries was significantly reduced ( 49.64 ± 6.40 vs 66.83 ± 6.00 , P lt ; 0.05 ) 4.45 days , the antibody-coated stent vascular neointimal hyperplasia in the distal end of the distal end than ordinary bracket vascular significantly lighter . However , no significant difference between the proximal end of the artery . Conclusion: gelatin as a substrate package stent is conducive to the CD34 antibody adsorption . 2.CD34 antibody-coated stents can effectively reduce the damaged artery stent stenosis .

Related Dissertations

  1. Performance Analysis of Anti-Multipath Capability in DSSS System and Study on the Compensation Methods,TN914.42
  2. The Research of Technology for 3D Fashion Virtual Distortion and Display,TS941.26
  3. Study on Evaluation of Stand Species Diversity in Nanping,S718.5
  4. Research and Design on Inverter of Stand-alone Wind Power Generation System,TM464
  5. Lattice Boltzmann Simulation of Hemodynamics in Cerebral Aneurysms,R743.3
  6. Narrow lumen automatic measurement system hardware design,TP274
  7. Applied to narrow gap SAW image acquisition and pre-processing System,TG445
  8. Wind turbine bearing testing machine key technology research,TH87
  9. Based on domestic devices for high power fiber lasers,TN248.1
  10. Single boom luffing jib portal crane system optimization design,TH213.4
  11. Study of SBS Suppression in Narrow-linewidth Fiber Amplifiers Based on Spectral Manipulation Technology,TN722
  12. Natural Biological Scaffold: a Novel Material for Abdominal Wall Reconstruction,R318.08
  13. Experimental Study on Repairing Critical Size Mandibular Defect with Porous Silk Fibroin Scaffold in Rabbit,R318.08
  14. Working Memory Event Encoding by Theta and Gamma Phase Oscillation of Multi-channel LFPs Based on Wigner-Ville Distribution,R318.0
  15. The Clinical Value of Narrow Band Imaging Endoscopy in Diagnosis of Superficial Esophageal Carcinoma and Precancerous Lesions,R735.1
  16. Three-dimensional computer reconstruction in narrow cranial disease diagnosis and surgery,R726.2
  17. On the provincial TV news stand desk,G229.24
  18. Study on Dual-wavelength Narrow line-width Fiber Ring Laser and Its Application,TN248
  19. Research of the Mathematic Model of Fine-line Screen Printing Process,TS871.1-4
  20. Technical and Economic Analysis of Winfarm Project,TM614
  21. A Study on the Distributed Growth Model of Chinese Fir Based on GIS and RS,S791.27

CLC: > Medicine, health > Internal Medicine > Heart, blood vessels ( circulatory ) disease > Heart disease > Coronary arteries ( atherosclerosis ),heart disease (CHD)
© 2012 www.DissertationTopic.Net  Mobile