Dissertation > Excellent graduate degree dissertation topics show
The Preliminary Observation of CD34 Antibody Coated Stents to Prevent In-stent Stenosis of Artery Injured by Balloon
Author: CaoHuaMing
Tutor: SuHai;WangXiaoHua
School: Jiangxi Medical College
Course: Internal Medicine
Keywords: CD34 antibody Stand Narrow Endothelial precursor cells
CLC: R541.4
Type: Master's thesis
Year: 2005
Downloads: 74
Quote: 2
Read: Download Dissertation
Abstract
|
Objective: observed in rabbits CD34 antibody coated stent ability to reduce and prevent the the balloon injury stent stenosis . Method : 1. Bracket Development : Comparative gelatin and low molecular weight dextran two stents package substrate , identified by gelatin as a package substrate stent coated , and then package the CD34 antibody . 2 animal model : the left and right femoral artery of New Zealand white rabbits using balloon injury , immediately after injury to the common stent implantation on the right , the left implant antibody bracket ; 14 days sampling a 45 days sampling 3 . OUTCOME MEASURES : ① angiography : stent narrow Percentage : narrow lumen in% = (stent diameter - the diameter of the narrowest point ) / stent diameter × 100 % . The ② pathological examination of the stented segment artery neointimal : OUTCOME MEASURES stent neointimal hyperplasia percentage . Calculate the the bracket enclosed area ( EEM ) , the arterial lumen area that endothelial cells surrounding area ( Lumen ) , neointimal area ( N ) = EEM - Lumen . Cross section artery percentage of N = ( the EEM - lumen ) / the EEL x 100 % ; the ③ bracket at both ends of the arterial wall. : To observe the indicators for both ends of neointimal hyperplasia . (4) data processing and statistics : All data are mean ± standard deviation , using a paired t-test . Results: 1.14 days , the antibody stent segment artery neointimal hyperplasia was significantly lower than the ordinary bracket side . 2.45 days, compared with the ordinary bracket , antibody-coated stent stenosis percentage was significantly down on the ordinary side of the bracket ( 16.13 ± 3.93 VS 47.03 ± 11.89 , P lt ; 0.05 ) ; 3 . The stent segments artery neointimal : antibody package artery stent segment neointimal percentage than ordinary stent segment arteries was significantly reduced ( 49.64 ± 6.40 vs 66.83 ± 6.00 , P lt ; 0.05 ) 4.45 days , the antibody-coated stent vascular neointimal hyperplasia in the distal end of the distal end than ordinary bracket vascular significantly lighter . However , no significant difference between the proximal end of the artery . Conclusion: gelatin as a substrate package stent is conducive to the CD34 antibody adsorption . 2.CD34 antibody-coated stents can effectively reduce the damaged artery stent stenosis .
|
Related Dissertations
- Performance Analysis of Anti-Multipath Capability in DSSS System and Study on the Compensation Methods,TN914.42
- The Research of Technology for 3D Fashion Virtual Distortion and Display,TS941.26
- Study on Evaluation of Stand Species Diversity in Nanping,S718.5
- Research and Design on Inverter of Stand-alone Wind Power Generation System,TM464
- Lattice Boltzmann Simulation of Hemodynamics in Cerebral Aneurysms,R743.3
- Narrow lumen automatic measurement system hardware design,TP274
- Applied to narrow gap SAW image acquisition and pre-processing System,TG445
- Wind turbine bearing testing machine key technology research,TH87
- Based on domestic devices for high power fiber lasers,TN248.1
- Single boom luffing jib portal crane system optimization design,TH213.4
- Study of SBS Suppression in Narrow-linewidth Fiber Amplifiers Based on Spectral Manipulation Technology,TN722
- Natural Biological Scaffold: a Novel Material for Abdominal Wall Reconstruction,R318.08
- Experimental Study on Repairing Critical Size Mandibular Defect with Porous Silk Fibroin Scaffold in Rabbit,R318.08
- Working Memory Event Encoding by Theta and Gamma Phase Oscillation of Multi-channel LFPs Based on Wigner-Ville Distribution,R318.0
- The Clinical Value of Narrow Band Imaging Endoscopy in Diagnosis of Superficial Esophageal Carcinoma and Precancerous Lesions,R735.1
- Three-dimensional computer reconstruction in narrow cranial disease diagnosis and surgery,R726.2
- On the provincial TV news stand desk,G229.24
- Study on Dual-wavelength Narrow line-width Fiber Ring Laser and Its Application,TN248
- Research of the Mathematic Model of Fine-line Screen Printing Process,TS871.1-4
- Technical and Economic Analysis of Winfarm Project,TM614
- A Study on the Distributed Growth Model of Chinese Fir Based on GIS and RS,S791.27
CLC: > Medicine, health > Internal Medicine > Heart, blood vessels ( circulatory ) disease > Heart disease > Coronary arteries ( atherosclerosis ),heart disease (CHD)
© 2012 www.DissertationTopic.Net Mobile
|