Dissertation > Excellent graduate degree dissertation topics show
Influence of Different Contrast’s Agent Dose on Multi-slice Spiral CT Liver Perfusion Image: An Experimental Study
Author: HuYueQun
Tutor: WangWei
School: Central South University
Course: Medical Imaging and Nuclear Medicine
Keywords: Tomography X - ray computed Perfusion imaging Contrast agent
CLC: R816.5
Type: Master's thesis
Year: 2011
Downloads: 18
Quote: 0
Read: Download Dissertation
Abstract
|
The purpose of using 64-slice spiral CT in experimental animals ( Chinese rural dogs ) whole liver perfusion scan and to explore CT perfusion imaging and perfusion parameters , seeking to optimize program . Materials and Methods 10 Chinese rural dogs as checked PHILIPS 64 - slice spiral CT liver the JOG perfusion mode using binoculars high-pressure syringe injection of contrast 0.5,0.8,1.0,2.0 mL / kg body weight dose and 5.0ml / s speed agents perfusion scan . Liver perfusion software as the cut-off point of the hepatic arterial phase and portal venous phase maximum enhancement of the renal cortex and spleen perfusion images processing and analysis and come to each dose , each of the reference images compliance rate under various organ perfusion parameters hepatic arterial perfusion (HAP), portal vein infusion amount ( HPP ) , total liver perfusion amount ( TLP ) , hepatic arterial perfusion index ( HAPI ) . The number of successful cases of 0.8 mL / kg dose of the quality of scanned images processing compliance rate was 100 % ; 0.8mL/kg doses , kidney and spleen as reference organ for post-processing of eight cases and six cases in both The success of the six cases . The dose to the kidney and spleen as reference organ perfusion parameters were treating the resulting HAP (29.88 ± 9.94) mL/min/100mg and (28.25 ± 2.19) mL/min/100mg, HPP (59.55 ± 10.11 ) the mL/min/100mg and ( 53.53 ± 10.71 ) mL/min/100mg . the TLP ( 89.43 ± 26.87 ) mL/min/100mg and ( 81.78 ± 18.56 ) mL/min/100mg , HPI ( 0.33 ± 0.06 ) mL / min / 100mg (0.30 ± 0.16) mL/min/100mg. The dose parameters were not significantly different ( P gt; 0.05 ) . Conclusion with PHILIPS 64 rows for dog liver whole liver the JOG ( light jump ) perfusion scan processing software image by different doses of compliance and liver perfusion analysis , discover 0.8mL/kg weight dose , 5.0ml / s injection speed enhancements to the kidney and spleen maximum value as a cut-off point of the hepatic artery and portal phase , can get the best of the post-processing effects .
|
Related Dissertations
- Image-Guided Adaptive Radiation Therapy of Intensity-Modulated Radiation for Cervical Cancer,R737.33
- Study the Protective Value of Spect Lung Perfusion to Lung Function in Esophageal Cancer Patients Treated with Radiotherapy,R735.1
- The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
- Assessment of Carotid Atherosclerotic Plaques with Multi-slice Spiral Computed Tomography Angiography and the Correlation of Ischemic Cerebrovascular Disease,R816.1
- Clinical Application Research of CT Urography in Mini-percutaneous Nephrolithotomy,R699
- Spectral CT Characterization of Urinary Calculi : in Vitro Experience,R691.4
- Combined Study of Susceptibility Weighted Imaging and Dynamical Susceptibility Contrasted Perfusion Imaging in Detection of Heterogeneity of Brain Neoplasms,R739.4
- Assessment of Efficicy of Transarterial Chemoembolization by Gelfoam Particles Using DSCT Perfusion Imaging for Hepatocellular Carcinoma,R735.7
- Research on Interstitial Lung Disorders of the Secondary Pulmonary Tuberculosis in HRCT,R521
- Without contrast agent -dimensional TOF MR angiography with France multidetector CT angiography in the diagnosis of lower extremity arterial disease comparative study,R816.2
- Multislice spiral computed tomography analysis of aortic sinus arrhythmia anatomical characteristics and clinical relevance,R541.7
- 16 -slice spiral CT MPR technique in the diagnosis of appendicitis clinical value,R656.8
- 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
- Lung cancer and benign lung tumor CT misdiagnosis and control study,R734.2
- Study of Quality Control of 64-slice CT Coronary Angiography in Diagnosis of Rheumatic Heart Disease Abstract,R816.2
- Uniform Image Quality Achieved by Individual Tube Current Modulation in Coronary CT Angiography: Preliminary Study,R816.2
- The Analysis of the Retinal Thickness in Refractory Amblyopia Eyes,R777.44
- The Diagnostic Value of Multi-slice Spiral CT Three-dimensional Reconstructions for Pulmonary Focal Ground-glass Opacity,R734.2
- Synthesis and Characterization of Two Novel Magnetic Resonance Imaging Contrast Agents,R914
- Study on Modeling and Optimal Design of Capacitively Coupled Electrical Resistance Tomography System,TP212
- Based on phase sensitive demodulation capacitive coupling resistance tomography study,TP391.41
CLC: > Medicine, health > Of Medical > Radiation Medicine > Each location and course of disease X - ray diagnosis and therapy > Stomach and digestive
© 2012 www.DissertationTopic.Net Mobile
|