Dissertation > Excellent graduate degree dissertation topics show

Influence of Different Contrast’s Agent Dose on Multi-slice Spiral CT Liver Perfusion Image: An Experimental Study

Author: HuYueQun
Tutor: WangWei
School: Central South University
Course: Medical Imaging and Nuclear Medicine
Keywords: Tomography X - ray computed Perfusion imaging Contrast agent
CLC: R816.5
Type: Master's thesis
Year: 2011
Downloads: 18
Quote: 0
Read: Download Dissertation

Abstract


The purpose of using 64-slice spiral CT in experimental animals ( Chinese rural dogs ) whole liver perfusion scan and to explore CT perfusion imaging and perfusion parameters , seeking to optimize program . Materials and Methods 10 Chinese rural dogs as checked PHILIPS 64 - slice spiral CT liver the JOG perfusion mode using binoculars high-pressure syringe injection of contrast 0.5,0.8,1.0,2.0 mL / kg body weight dose and 5.0ml / s speed agents perfusion scan . Liver perfusion software as the cut-off point of the hepatic arterial phase and portal venous phase maximum enhancement of the renal cortex and spleen perfusion images processing and analysis and come to each dose , each of the reference images compliance rate under various organ perfusion parameters hepatic arterial perfusion (HAP), portal vein infusion amount ( HPP ) , total liver perfusion amount ( TLP ) , hepatic arterial perfusion index ( HAPI ) . The number of successful cases of 0.8 mL / kg dose of the quality of scanned images processing compliance rate was 100 % ; 0.8mL/kg doses , kidney and spleen as reference organ for post-processing of eight cases and six cases in both The success of the six cases . The dose to the kidney and spleen as reference organ perfusion parameters were treating the resulting HAP (29.88 ± 9.94) mL/min/100mg and (28.25 ± 2.19) mL/min/100mg, HPP (59.55 ± 10.11 ) the mL/min/100mg and ( 53.53 ± 10.71 ) mL/min/100mg . the TLP ( 89.43 ± 26.87 ) mL/min/100mg and ( 81.78 ± 18.56 ) mL/min/100mg , HPI ( 0.33 ± 0.06 ) mL / min / 100mg (0.30 ± 0.16) mL/min/100mg. The dose parameters were not significantly different ( P gt; 0.05 ) . Conclusion with PHILIPS 64 rows for dog liver whole liver the JOG ( light jump ) perfusion scan processing software image by different doses of compliance and liver perfusion analysis , discover 0.8mL/kg weight dose , 5.0ml / s injection speed enhancements to the kidney and spleen maximum value as a cut-off point of the hepatic artery and portal phase , can get the best of the post-processing effects .

Related Dissertations

  1. Image-Guided Adaptive Radiation Therapy of Intensity-Modulated Radiation for Cervical Cancer,R737.33
  2. Study the Protective Value of Spect Lung Perfusion to Lung Function in Esophageal Cancer Patients Treated with Radiotherapy,R735.1
  3. The Clinic Value of Diffusion Weighted Whole Body Imaging with Background Body Signal Suppression (DWIBS) Compared with hPET/CT,R445.2
  4. Assessment of Carotid Atherosclerotic Plaques with Multi-slice Spiral Computed Tomography Angiography and the Correlation of Ischemic Cerebrovascular Disease,R816.1
  5. Clinical Application Research of CT Urography in Mini-percutaneous Nephrolithotomy,R699
  6. Spectral CT Characterization of Urinary Calculi : in Vitro Experience,R691.4
  7. Combined Study of Susceptibility Weighted Imaging and Dynamical Susceptibility Contrasted Perfusion Imaging in Detection of Heterogeneity of Brain Neoplasms,R739.4
  8. Assessment of Efficicy of Transarterial Chemoembolization by Gelfoam Particles Using DSCT Perfusion Imaging for Hepatocellular Carcinoma,R735.7
  9. Research on Interstitial Lung Disorders of the Secondary Pulmonary Tuberculosis in HRCT,R521
  10. Without contrast agent -dimensional TOF MR angiography with France multidetector CT angiography in the diagnosis of lower extremity arterial disease comparative study,R816.2
  11. Multislice spiral computed tomography analysis of aortic sinus arrhythmia anatomical characteristics and clinical relevance,R541.7
  12. 16 -slice spiral CT MPR technique in the diagnosis of appendicitis clinical value,R656.8
  13. 3.0T high-field magnetic resonance imaging of the central type lung cancer preliminary study,R734.2
  14. Lung cancer and benign lung tumor CT misdiagnosis and control study,R734.2
  15. Study of Quality Control of 64-slice CT Coronary Angiography in Diagnosis of Rheumatic Heart Disease Abstract,R816.2
  16. Uniform Image Quality Achieved by Individual Tube Current Modulation in Coronary CT Angiography: Preliminary Study,R816.2
  17. The Analysis of the Retinal Thickness in Refractory Amblyopia Eyes,R777.44
  18. The Diagnostic Value of Multi-slice Spiral CT Three-dimensional Reconstructions for Pulmonary Focal Ground-glass Opacity,R734.2
  19. Synthesis and Characterization of Two Novel Magnetic Resonance Imaging Contrast Agents,R914
  20. Study on Modeling and Optimal Design of Capacitively Coupled Electrical Resistance Tomography System,TP212
  21. Based on phase sensitive demodulation capacitive coupling resistance tomography study,TP391.41

CLC: > Medicine, health > Of Medical > Radiation Medicine > Each location and course of disease X - ray diagnosis and therapy > Stomach and digestive