Dissertation > Excellent graduate degree dissertation topics show
Studies on Sol-Gel Based Glucose Biosensors and Carbon Nanotube-Modified Electrodes
Author: XiXia
Tutor: LiuJie
School: Nantong University
Course: Aviation, aerospace and maritime medicine
Keywords: electrochemically platinized carbon paste immobilization of enzyme amperometry sol-gel glucose biosensor nifedipine Sudan I voltammetry carbon nanotube chemically modified electrode
CLC: R318.6
Type: Master's thesis
Year: 2007
Downloads: 95
Quote: 0
Read: Download Dissertation
Abstract
|
Objective: To develop a new design of amperometric glucose biosensors based on the enzyme immobilization onto an electrochemically platinized carbon paste matrix modified with sol-gel, and examine the unique electroanalytical performance of the prepared biosensor.To fabricate the multi-wall carbon nanotube (MWCNT) modified electrode and study the electrochemical behaviors of nifedipine (NIF) and Sudan I and their determinations at the MWCNT modified electrode.Methods: The new amperometric glucose biosensor was prepared by immobilizing the glucose oxidase (GOD) onto the electrochemically platinized carbon paste followed by modification with silicon sol-gel. Amperometric detection was conducted to examine the electrochemical responses of glucose substrate at the developed glucose biosensor.A combination of three commonly used voltammetric techniques, namely cyclic voltammetry (CV), differential pulse voltammetry (DPV) and linear sweep voltammetry (LSV) was employed to determine the electrochemical behaviors of NIF and Sudan I at the MWCNT modified electrode, thus developing a new electroanalytical method for the analytes.Results: The unique voltammetric profile was shown for the developed glucose biosensor, suggesting that it allowed ameperometric detection with a reduction mode at low potentials around 0V. Cathodic currents were induced upon successive additions of glucose at the operating potential of 0V (vs. Ag/AgCl), presenting a well defined linearity for the concentration dependence. The biosensor also showed good selectivity due to the elimination of interferences from endogenous species and long-term stability in that about 90% of original activity was retained following 45-day storage of the biosensor.The reduction peak current of NIF was enhanced significantly at the MWCNT modified glassy carbon electrode (GCE), in contrast to that at the bare GCE. Under the optimized experimental conditions, the reduction peak current varied linearly with the concentration of NIF over the range from 7.5×10-8 to 2.5×10-5 mol·L-1 with a detection limit of 2.5×10-8 mol·L-1. The relative standard deviation (RSD) for 1.0×10-6 mol·L-1 NIF is approximately 4.6% (n=10).Sudan I yielded a well-defined and sensitive reduction peak at the MWCNT modified electrode in 0.1 mol·L-1 phosphate buffer solution (PBS, pH 7.0). Under the optimized experimental conditions, the reduction peak current varied linearly with the concentration of Sudan I over the range from 6.0×10-7 to 7.5×10-5 mol·L-1 with a detection limit of 2.0×10-7 mol·L-1. RSD for 2.0×10-5 mol·L-1 Sudan I is approximately 4.8% (n=10).Conclusion: Our developed glucose biosensor can be used for monitoring the glucose concentration in biological fluids and other applications in biotechnological areas.The MWCNT modified GCE exhibits catalytic activity to the reduction of NIF and Sudan I. The proposed method is simple, rapid and sensitive, and can be used for the determination of NIF in pharmaceutical formulations and Sudan I in chili powder.
|
Related Dissertations
- Preparation and Photocatalytic Properties for Water Decomposition of Titanate Photocatalyst,O643.36
- Preparation of ITO Quai-1D Nanostructures by Sol-Gel Method Combined with Porous Anodic Aluminum Oxide Template,TB383.1
- Study on the Synthesis Bi3.25La0.75Ti3O12(BLT) Nanotubes and Nano Wires,TB383.1
- Preparation and Electrocaloric Effect of BaxSr1-xTiO3 Ferroelectric Thin Films,TB383.2
- Preparation and Performance of V2O5-WO3/MOx/Cordierite Catalyst Modified with Cu、Mn、Ce for DeNOx,X701
- Preparation, Characterization and Application of Prussian Blue Composite Nanomaterials,TB383.1
- Iron, lanthanum -doped nano TiO \u003csub\u003e 2 \u003c/ sub\u003e Preparation and photocatalytic properties,O614.411
- Electrochemical Studies on Interaction between ApoCopC、BSA and Cu(Ⅱ)、Cu(Ⅰ)、Cd(Ⅱ)、Ag(Ⅰ),O646
- Carbon Nanotubes Compound Polymer Film Modified Electrode and Its Application for Electroanalytical Chemistry,O657.1
- The Fabrication and Application of the Preanodized Inlaying Ultrathin Carbon Paste Film Electrode,O657.1
- Cobalt Ferrite and Its Performance,O611.4
- Nano Pt / SiC Preparation, Characterization and Electrochemical Catalytic Performance,TM911.4
- Growth of Single-walled Carbon Nanotube Arrays and the Study of Their Adhesion Force,TB383.1
- Preparation of Silica Hollow Spheres with Mesopores in the Walls,TB383.1
- Fabrications and Applications of Microelectrode Array of Silicon Dioxide Cavities and Magnetic Ferroferric Oxide Nano-Bioconjunctions,TB383.1
- Study on Preparation and Properties of Polyimide/SiO2 Hybrid Films,TB383.2
- Research on the Synthesis of the Pr-zircon Yellow Pigments and the Ceratmic Ink,TQ622.1
- The Research on Preparation Technology and Sintering Behavior of Rare Earth Aluminates (Dy3Al5O12、 NdAlO3、LaAl11O18),TB383.3
- Studies of High Refractive Index Materials Prepared by Nano ZrO2 and TiO2 Hybrid Silicone Epoxy Resin,TB383.1
- Preparation and Characterization of Al2O3/C Hybrid Aerogels and Al2O3 Aerogels,O648.17
- Preparation and Characteristic of BiFeO3 /Bi3.25 La 0.75 Ti3O12 Multiferroic Bi-layer Films,O484.4
CLC: > Medicine, health > Basic Medical > Medical science in general > Biomedical Engineering > Apparatus, equipment
© 2012 www.DissertationTopic.Net Mobile
|