Research and Design of Portable High-precision Spectrometer for the Radioactivity in Architectural Materials Based on Pc/104
Author: LiZhiHua
Tutor: KongLi
School: Huazhong University of Science and Technology
Course: Detection Technology and Automation
Keywords: Detection of radioactive materials PC/104 Peak hold Spectroscopy data processing Application software design
CLC: TH87
Type: Master's thesis
Year: 2004
Downloads: 194
Quote: 3
Read: Download Dissertation
Abstract
|
With the continuous improvement of human understanding of the quality of the environment, the issue of radioactivity in building materials more and more people's attention. Rays emitted by radioactive substances on the human body damage caused by the imperceptible internal and external irradiation. Radioactivity Levels before the use of building materials for building materials is an important means to reduce radioactive contamination. In this paper, the gamma-ray detection theory and technology of domestic and foreign practice of building materials radioactive detection depth study. Domestic and outside the building materials radioactive detector multi commercial computer, standard computer card with the function of the instrument, such as radiation detection probe combined into a test platform and virtual detector, such high accuracy spectrometer, friendly interface portable measurement can not meet the site requirements. Microcontroller as the main form of radioactive detector volume, low power consumption suitable for field measurements portable, but the limitations of the microcontroller function is difficult to implement complex data processing functions, so accuracy is often relatively poor, and the man-machine interface is not very good. The paper mainly discussed based on the radioactive detection principle as well as the overall system implementation, design and development of a PC/104 as the core, by a scintillation counter, pulse shaping and amplifying circuit, the peak hold device PKD-01, ISA capture cards PM510, application software, etc. constitute the pulse peak detection and gamma spectroscopy data acquisition system; sources of error of the system, based on the research presented both to improve the signal-to-noise ratio, reducing the statistical EDS analysis of the fluctuations of the data processing method of least squares to move smoothing method \method; paper also proposed to ensure the measurement accuracy of the system \Finally, the man-machine interface, interrupt collection procedures, serial communication program application software design. Through more development work, the system not only has a friendly interface, high detection accuracy, but also portable for field measurements of building materials production fully automated, computer-based building materials radioactive detector, the instrument detected in radioactive materials effects and good prospects for the application.
|
Related Dissertations
- VxWorks-based control system and observation,TP273
- The Research on the In-Vehicle Online Compaction Detection System,U416.06
- Motion Controller Design and Its Application in spray equipment,TP273
- An Integrated Tester Development for the Aircraft Relay Box,V243
- Design and Application of Industrial Control Platform Based on PC/104 and ARM,TP273
- Study and Design of the Intelligent Control System for Power Line Inspection Robot,TP242
- Research and Implementation of Extended Systems about PC/104 Bus Controller and Multi-UART Based on FPGA,TP273
- Design and Implementation about Semi-physical Simulation System Platform for Ship Motion Based on VxWorks,U661
- The Design of Control System on Single-Axis Turntable,TH703
- Research and Design of CNC System Using ARM Processor,TG659
- Research of Acoustic Detect Emulational System Software on Underwater Robot Under VxWorks,TP242.3
- ARM embedded platform design of the three anti- system of air defense fortifications nuclear, biological and chemical,TP273
- Research of GFSINS Navigation Computer System Based on PC/104 Bus,TN965.8
- Adaptive Model Following Control for Test Turntable,TP273
- Linux-based lithium-ion battery Laser Cutting Control System Design,TP273
- Control System Design of High-voltage Power Line Inspection Robot Based on PC/104,TM76
- Study on Image Capture System Based on Goal Coordinate Locating System,TP391.41
- The Heart Sound、the Pulse Signal Gathering System Based on SCM,TP29-AI
- Study of Marine Plankton Image Capture System in Real Time,TP274.2
- Design and Simulation of the Solar Tracking System,F203
- A GUN fault detector data acquisition and communication system design,TP274.2
CLC: > Industrial Technology > Machinery and Instrument Industry > Instruments, meters > Material testing machine and test equipment
© 2012 www.DissertationTopic.Net Mobile
|